Document IIF
Une technologie innovante pour adapter les systèmes frigorifiques de supermarché au R-744 transcritique à la hausse des températures.
A novel technology to adapt transcritical R744 supermarket refrigeration systems to rising temperatures.
Numéro : 1131
Auteurs : GULLO P., KORSHIDI V., FUNDER-KRISTENSEN T., GURUCHETHAN A. M., MORID ZADEH M., FOLIACO B.
Résumé
In this work a novel technology to adapt transcritical R744 supermarket refrigeration systems to warm and hot climates as well as to rising temperatures was proposed and exhaustively investigated. The novel solution consisted of a booster device (increasing the transcritical fluid R744 pressure) followed by an air-cooled gas cooler and located between the conventional air-cooled condenser/gas cooler and high-pressure expansion valve. The results obtained revealed energy savings by from 2.31 % to 2.91 % in Seville (Spain) and from 4.64 % to 5.73 % in New Delhi (India). To further increase the energy benefits from the proposed technology, the use of an expander replacing the high-pressure expansion valve was also considered. As a consequence, energy savings by 7.80 % in Seville and 14.44 % in New Delhi with an additional investment recovery time of about 3 years in both of the selected locations were assessed.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A novel technology to adapt transcritical R744 supermarket refrigeration systems to rising temperatures.
- Identifiant de la fiche : 30034180
- Langues : Anglais
- Sujet : Technologie
- Source : 1st IIR International Conference on Refrigeration Adapting to Rising Temperatures
- Date d'édition : 08/2025
- DOI : http://dx.doi.org/10.18462/iir.adaptation.2024.1131
Liens
Voir d'autres communications du même compte rendu (45)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : R744; Supermarché; COP; Refroidisseur d'air; Détendeur
-
CO2 gas cooler performance on-site.
- Auteurs : HEERUP C., BRAMSEN F.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Optimization of two-stages CO2 transcritical cy...
- Auteurs : TRABUCCHI S., ORLANDI M.
- Date : 11/04/2019
- Langues : Anglais
- Source : 8th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, Avril 11-13, 2019.
- Formats : PDF
Voir la fiche
-
Monitoring of a CO2 commercial refrigeration sy...
- Auteurs : DUGARIA S., AZZOLIN M., CALABRESE L., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Multi ejector and pivoting-supported R744 appli...
- Auteurs : CONTIERO L., PARDIÑAS A. A., HAFNER A.
- Date : 16/09/2021
- Langues : Anglais
- Source : 9th IIR Conference on Ammonia and CO2 Refrigeration Technologies. Proceedings: Ohrid, North Macedonia, 16-17 September, 2021
- Formats : PDF
Voir la fiche
-
Simulation and monitoring of a CO2 c...
- Auteurs : AZZOLIN M., CATTELAN G., GIOIA-CARABELLESE de C., DUGARIA S., MINETTO S., DEL COL D.
- Date : 13/01/2021
- Langues : Anglais
- Source : 10th IIR Conference on Compressors and Refrigerants.
- Formats : PDF
Voir la fiche