Valeurs R optimales des parois d'immeubles dans diverses conditions climatiques au Royaume d'Arabie Saoudite.
Optimum R-values of building walls under different climatic conditions in the Kingdom of Saudi Arabia.
Auteurs : SANEA S. A. al-, ZEDAN M. F., MUJAHID A. M. al-, et al.
Type d'article : Article
Résumé
This paper deals with the determination of optimum R-values for building walls under different climatic conditions in the Kingdom of Saudi Arabia (KSA); namely, Riyadh, Jeddah, and Abha. One-layered and two-layered walls made of concrete and red clay blocks are considered. Molded polystyrene, polyurethane board, and rock wool are used as insulation materials. Thermal and economic analyses are carried out in order to determine the optimum insulation thickness (Lopt). The thermal analysis involves calculating temperature distribution and its variation with time across wall sections under steady periodic conditions. This is done by utilizing a previously validated computer model based on the finite-volume implicit method. Yearly transmission loads are calculated for different insulation thicknesses and used in an economic model, based on the present worth method, in order to optimize the insulation thickness and consequently determine the optimum R-values. Cooling and heating loads are separated and treated with different costs. For Riyadh and Jeddah, the optimum R-values are found in the range 2.00 to 2.90 m2.K/W, while those for Abha are found in the range 1.34 to 1.99 m2.K/W. Payback periods determined at Lopt, while considering effect of inflation and discount rates, are found in the range 3 to 10 years.
Détails
- Titre original : Optimum R-values of building walls under different climatic conditions in the Kingdom of Saudi Arabia.
- Identifiant de la fiche : 30016678
- Langues : Anglais
- Sujet : Environnement
- Source : Applied Thermal Engineering - vol. 96
- Date d'édition : 05/03/2016
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.11.072
Liens
Voir d'autres articles du même numéro (32)
Voir la source
Indexation
-
Thèmes :
Domaines connexes au froid;
Bâtiments écologiques - Mots-clés : Analyse thermique; Arabie saoudite; Immeuble; Performance; Paroi; Isolation; Confort thermique
-
Zele spozywcze struckura i wlasciwosci.
- Auteurs : KRYSTYJAN M., CIESIELSKI W.
- Date : 02/2016
- Langues : Polonais
- Source : Przemysl Spozywczy - vol. 70 - n. 2
Voir la fiche
-
Experimental investigation of radiation effect ...
- Auteurs : ARSLANOGLU N., YIGIT A.
- Date : 05/01/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 92
Voir la fiche
-
A three-dimensional CFD simulation study to red...
- Auteurs : PEREZ J. A., OROSA J.A., GRUEIRO T.
- Date : 05/02/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 94
Voir la fiche
-
Vliv tepelných ztrát rozvodu a ochlazování otop...
- Auteurs : SPURNÝ J., KABRHEL M.
- Date : 02/2017
- Langues : Tchèque
- Source : Vytápení Vetrání Instalace - vol. 26 - n. 1
- Formats : PDF
Voir la fiche
-
Choice of insulation standard for pipe networks...
- Auteurs : LUND R., MOHAMMADI S.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche