Validation des états permanents et transitoires de pompes à chaleur utilisant des frigorigènes alternatifs à faible GWP.
Steady state and transient validation of heat pumps using alternative lower GWP refrigerants.
Numéro : pap. 2266
Auteurs : BHANOT V., BACELLAR D., LING J., et al.
Résumé
The need for making a shift from refrigerants with high Global Warming Potential (GWP) to those with lower GWP is becoming increasingly important. A broad spectrum of alternative refrigerants have been proposed and their performance needs to be investigated through simulation and testing. To evaluate the performance of these candidates, the Air Conditioning, Heating and Refrigeration Institute (AHRI) has announced an industry-wide research program for studying the performance of low GWP refrigerants for major product categories such as air conditioners, heat pumps, chillers and refrigerators. One such study investigated alternatives to R410A, namely R32, D2Y60 and L41a. The investigation was conducted using a 3-ton residential split heat pump unit. This paper presents Simulink® -based steady state and transient analysis of the heat pump unit using two of the alternative refrigerants, R32 and D2Y60. A simplified, finite control volume approach is used to model the heat exchangers, while the expansion valve and compressor are treated as quasi-steady state components. The steady state and transient results compare well with measured data and the transient trends of the model are reproduced as expected, although with faster system response due to the exclusion of a TXV and accumulator. The proposed model can reasonably predict both steady state and transient performance of the heat pump for all the refrigerants analyzed under the operating conditions simulated. The results show that comparable capacities to the R410A baseline can be obtained using R32, although with a lower COP due to degradations in compressor efficiencies. For D2Y60 cycles, the capacities and COP are generally lower than the baseline cycle.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Steady state and transient validation of heat pumps using alternative lower GWP refrigerants.
- Identifiant de la fiche : 30013238
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
Indexation
-
Testing, simulation and soft-optimization of R4...
- Auteurs : ALABDULKAREM A., ELDEEB R., HWANG Y., et al.
- Date : 12/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 60
- Formats : PDF
Voir la fiche
-
Modelica based heat pump model for transient an...
- Auteurs : LING J., ALABDULKAREM A., QIAO H. T., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Nytt på köldmediefronten: alternativa köldmedie...
- Auteurs : MAKHNATCH P., KHODABANDEH R., PALM B.
- Date : 2012
- Langues : Suédois
- Source : KYLA+ Värmepumpar - n. 6
Voir la fiche
-
Drop in life cycle climate performance of low G...
- Auteurs : LI G., ALABDULKAREM A., HWANG Y., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Evaluation and soft-optimization for R410A low-...
- Auteurs : ALABDULKAREM A., ELDEEB R., HWANG Y., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche