Validation expérimentale des modèles d'efficacité constante pour les sous-systèmes d'un système de traitement d'air innovant à base de déshydratant et étude de la performance du système.
Experimental validation of constant efficiency models for the subsystems of an unconventional desiccant-based Air Handling Unit and investigation of its performance.
Auteurs : ANGRISANI G., ROSELLI C., SASSO M.
Type d'article : Article
Résumé
Desiccant-based Air Handling Units, thermally activated by solar collectors or cogenerators, are without any doubt an interesting alternative for solving problems of electrical over-consumption in traditional vapour compression air conditioning. In this paper, theoretical existing models for the operation of the main subsystems of a desiccant airconditioning system are experimentally calibrated and validated through a wide number of measurements in the typical summer operating range for these systems. The operation of each subsystem is described by a specific efficiency factor. In particular, the validity of the assumption for efficiency factors presenting constant values is experimentally investigated. For each subsystem, the average value of the selected efficiency factor is calculated. The values of standard deviations are rather low (lower than 0.092), suggesting that the constant efficiency hypothesis is reasonable within the range of operating conditions investigated. The validity of the assumed models has been confirmed by the evaluation of the Root Mean Standard Error (RMSE) that compares experimental and simulated values for each subsystem. RMSE lower than 1.3°C and 0.30 g/kg, respectively for temperature and humidity ratio, has been calculated. The desiccant wheel model has been used to evaluate its performance, e.g. in terms of Moisture Removal Capacity (ranging from 2.6 to 4.8 kg/h). Finally, a model of the whole system has been developed to estimate its performance, e.g. the Coefficient of Performance (ranging from 0.50 to 0.92). The results obtained with the experimentally validated models are in good agreement with the scientific literature.
Détails
- Titre original : Experimental validation of constant efficiency models for the subsystems of an unconventional desiccant-based Air Handling Unit and investigation of its performance.
- Identifiant de la fiche : 30005526
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 33-34
- Date d'édition : 02/2012
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2011.09.018
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
-
VAPEUR D'EAU DANS L'AIR : DESHUMIDIFICATION ET ...
- Date : 1991
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - vol. 46 - n. 730
Voir la fiche
-
A review of desiccant cooling systems.
- Auteurs : WAUGAMAN D. G., KINI A., KETTLEBOROUGH C. F.
- Date : 1993
- Langues : Anglais
- Source : J. Energy Resour. Technol. - vol. 115 - n. 1
Voir la fiche
-
A new configuration of the desiccant dehumidifi...
- Auteurs : KABEEL A. E., ABDELGAIED M.
- Date : 07/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 103
- Formats : PDF
Voir la fiche
-
An experimental investigation of optimization t...
- Auteurs : PARK B., KATO S., LEE S.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Simulation of advanced gas-fired desiccant cool...
- Auteurs : WOREK W. M., ZHENG W., BELDING W. A., et al.
- Date : 1991
- Langues : Anglais
Voir la fiche