Document IIF
Vapeur d'eau en tant que frigorigène : faisabilité commerciale.
The commercial feasibility of the use of water vapour as a refrigerant.
Auteurs : LACHNER B. F. Jr, NELLIS G. F., REINDL D. T.
Type d'article : Article, Article de la RIF
Résumé
This paper investigates the economic feasibility of a water-based vapor compression chiller with a nominal capacity of 3520 kW (1000 ton). Simplified models of potential cycle configurations are developed and used as a screening tool to identify a baseline cycle, the most attractive configuration for a water-based refrigeration machine. More detailed component-level models are developed to accurately size equipment and predict both the performance and cost of the baseline chiller. These component models address issues that are particularly crucial when water is used in refrigeration cycles, such as compression ratio, compressor discharge superheat and refrigerant-side pressure drop. Where possible, these component models are verified through comparison against the current state-of-the-art technology for large chillers that use R-134a as the refrigerant. The capital cost and expected operating costs are determined in order to quantify the payback and life-cycle costs associated with using water as a refrigerant, relative to traditional halocarbon refrigerants currently in use. Other issues that may have an economic impact on the feasibility of water as a viable alternative to traditional synthetic refrigerants are discussed, including purging and condensation within the compressor. The results show that water-based vapor compression refrigeration systems will not be economically attractive without substantial and successful efforts to develop low-cost, high capacity compressors. The paper provides an indication of the cost targets that must be met in order to make water vapor refrigeration systems practical.
Documents disponibles
Format PDF
Pages : 699-708
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The commercial feasibility of the use of water vapour as a refrigerant.
- Identifiant de la fiche : 2007-0970
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 4
- Date d'édition : 06/2007
Liens
Voir d'autres articles du même numéro (15)
Voir la source
Indexation
- Thèmes : HFC
- Mots-clés : R134a; Comparaison; Vapeur; Refroidisseur; Frigorigène; Eau
-
Comparison of screw compressors in liquid chill...
- Date : 11/2000
- Langues : Anglais
- Source : Afr. Heat. Cool. - vol. 1 - n. 4
Voir la fiche
-
Flow fields in shell-and-tube condensers: compa...
- Auteurs : KARLSSON T., VAMLING L.
- Date : 08/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 5
- Formats : PDF
Voir la fiche
-
Velocity of sound for R125, R134a, R143A, and t...
- Auteurs : AVSEC J., MARCIC M., LEIPERTZ A., et al.
- Date : 03/10/2001
- Langues : Anglais
- Source : Thermophysical Properties and Transfer Processes of New Refrigerants.
- Formats : PDF
Voir la fiche
-
The use of refrigerant R134a as model fluid for...
- Auteurs : SPINDLER K.
- Date : 03/10/2001
- Langues : Anglais
- Source : Thermophysical Properties and Transfer Processes of New Refrigerants.
- Formats : PDF
Voir la fiche
-
Vapour pressure measurements on 1,1,1,2-tetrafl...
- Auteurs : MAGEE J. W., HOWLEY J. B.
- Date : 1992
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 15 - n. 6
- Formats : PDF
Voir la fiche