Ventilation d’un parking fermé : conception, inconvénients et systèmes hybrides.
Enclosed car park ventilation – design, pitfalls and hybrid systems.
Auteurs : GOLDSCHMIDT T.
Type d'article : Article
Résumé
As cars are parked within an underground parking structure, Carbon Monoxide (CO) and other exhaust fumes are emitted into the atmosphere. There is a need for an efficient ventilation system that can remove these toxins, circulate fresh air, and assist fire fighters in case of an emergency. There are two traditional options for this task: ducted or ductless ventilation. Ducted ventilation is heavily used in the US and other global markets. While this has been the standard for many years, innovations in the field of ventilation have shifted the conventional ventilation system towards ductless designs. Ductless designs use jet fans to dilute and remove contaminants and control the smoke. These systems provide greater control at a fraction of the cost of traditional ducted systems. In regions where ductless ventilation is not acceptable, a hybrid system combining ducted and ductless may be used.
Documents disponibles
Format PDF
Pages : 18-36
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Enclosed car park ventilation – design, pitfalls and hybrid systems.
- Identifiant de la fiche : 30021656
- Langues : Anglais
- Sujet : Généralités
- Source : Air Conditioning and Refrigeration Journal - vol. 19 - n. 5
- Date d'édition : 10/2016
Liens
Voir d'autres articles du même numéro (1)
Voir la source
Indexation
- Thèmes : Qualité de l'air intérieur
- Mots-clés : Jet; Généralité; Ventilation; Ventilateur; Performance; Monoxyde de carbone; Coût
-
Car park ventilation system: performance evalua...
- Auteurs : CHAN M. Y., CHOW W. K.
- Date : 06/2004
- Langues : Anglais
- Source : Build. Environ. - vol. 39 - n. 6
Voir la fiche
-
Siting of domestic carbon monoxide detectors.
- Auteurs : ROSS D. I.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
Ventilation multifonction à récupération de cha...
- Auteurs : MIYAMOTO T., NAKANO H.
- Date : 09/1993
- Langues : Japonais
- Source : Refrigeration - vol. 68 - n. 791
Voir la fiche
-
Pack-and-go IAQ monitoring.
- Auteurs : LATKO M. A.
- Date : 01/1998
- Langues : Anglais
- Source : Eng. Syst. - vol. 15 - n. 1
Voir la fiche
-
MESURE COMBINEE DE LA QUALITE DE L'AIR AMBIANT.
- Auteurs : SAUTTER L.
- Date : 08/1987
- Langues : Allemand
- Source : Heiz. Lüft.-Klima Haustech. - vol. 38 - n. 8
Voir la fiche