Résumé
Estimation of refrigerant distribution in adsorbent bed is important to design an adsorber of an adsorption refrigerating system, because the adsorption and desorption process is complex phenomena with heat and mass transfer, and strongly effects on the cycle performance. The adsorbed refrigerant distribution in a rectangular adsorber was visualized and measured by a neutron radiography method for activated carbon and ethanol pair. Quantitative measurement of adsorbed refrigerant amount was realized by applying the umbra method to compensate neutron scattering effect. It was confirmed from the visualization of adsorbent in equilibrium that the measured results from the radiographs were agreed well with the previous data measured by a weight method. In the experiments of adsorption and desorption process with heat transfer, transient behaviors of adsorbed refrigerant distribution could be clearly visualized. It was clarified from the results that the refrigerant adsorption was dominated by heat diffusion in the adsorbent bed, and adsorbed amount became higher around the heat-transfer surface including fins.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Visualization and measurement of adsorption and desorption process in activated carbon/ethanol pair adsorber.
- Identifiant de la fiche : 30015104
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0067
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Carbone; Mesure; Adsorption; Adsorbeur; Éthanol; Désorption; Frigorigène
-
Isothermal adsorption measurement for the devel...
- Auteurs : SAHA B. B., KOYAMA S., ALAM K. C. A., et al.
- Date : 04/12/2002
- Langues : Anglais
- Source : Green breeze from Asia: frontiers of refrigerants, heat transfer and system.. ACRA-2002. Proceedings of the Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Transient simulation of finned tube type adsorb...
- Auteurs : JRIBI S., MIYAZAKI T., SAHA B. B., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Optimized performance of one bed adsorption coo...
- Auteurs : MIYAZAKI T., SHARKAWY I. I. el-, SAHA B. B., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A study on thermophysical characteristics of ac...
- Auteurs : MAKIMOTO N., HU B., KOYAMA S.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Determination of the isosteric heat of hydrogen...
- Auteurs : ZHENG Q. R., GU A. Z., LIN W. S., et al.
- Date : 24/09/2002
- Langues : Anglais
- Source : Proceedings of the International Sorption Heat Pump Conference.
Voir la fiche