Document IIF

Optimisation appliquée d'un détendeur à double vis pour la production d'énergie électrique dans un système de récupération de chaleur perdue en utilisant un fluide actif organique.

Applied optimisation of a twin screw expander for electrical power generation in a waste heat recovery system using an organic working fluid

Résumé

This research investigates the applied optimisation of a twin screw expander which forms part of a prototype Controlled Phase Cycle (CPC) application, addressing the energy trilemma of emissions reduction, security of supply and cost savings in industrial environments. The optimisation of the expander’s performance affords an opportunity to improve on the low conversion efficiencies displayed by current ORC waste heat recovery systems, with projected CPC efficiencies upward of 6%.
The system uses R1233zd (E) as the organic working fluid and is designed to generate 80 kW of electrical power by harnessing a 1 MW thermal low pressure steam supply. A comparison of theoretically and empirically derived elements, including the effects of Built in Volume Ratio (BIVR), fluid gas fraction, mass flow rate, pressure and temperature on the expander’s operation enable the validation and quantification of optimised expander operation.

Documents disponibles

Format PDF

Pages : 7

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Applied optimisation of a twin screw expander for electrical power generation in a waste heat recovery system using an organic working fluid
  • Identifiant de la fiche : 30027643
  • Langues : Anglais
  • Source : IIR Rankine Conference 2020.
  • Date d'édition : 31/07/2020
  • DOI : http://dx.doi.org/10.18462/iir.rankine.2020.1114

Liens


Voir d'autres communications du même compte rendu (75)
Voir le compte rendu de la conférence