Résumé
To facilitate the extensive application of the flammable refrigerant propane (R290), accurate fault prediction is paramount. However, historical studies have predominantly relied on ‘refrigerant undercharge’ experiments—static states with fixed low charges—as surrogates for leakage. This approach fails to capture the
dynamic transient behavior of an active leak. Addressing this gap, this research proposes a predictive model validated through real-time dynamic leakage tests. These tests were utilizing capillary tubes to simulate continuous refrigerant loss, thereby providing a rigorous dataset for model validation. Experimental data from
actual refrigerant leakage scenarios were subsequently utilized to eliminate theoretical characteristic parameters exhibiting Pearson correlation coefficients lower than 0.85. We utilized transfer learning to develop the predictive model. The BiLSTM-FT model demonstrated robust adaptability, achieving a 17.65% reduction in Mean
Absolute Error (MAE), a 16.67% decrease in Root Mean Squared Error (RMSE), and a 4.50% increase in the coefficient of determination (R²) compared to standard RNN and LSTM baseline models. Furthermore, the CNNFT model for leakage location identification exhibited superior generalization capabilities, identifying leak
sources with an accuracy exceeding 0.91 across all tested conditions. Notably, compared to traditional classification models (RF, SVM), the CNN-FT model improved diagnostic accuracy by 46.74% under maximum operational cooling conditions and by 62.13% under minimum operational cooling conditions. The findings demonstrate the models' robust applicability to air conditioners at cross-conditions, providing a powerful tool for enhancing safety and efficiency in the management of these systems.
Documents disponibles
Format PDF
Pages : 18 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A study on leakage fault prediction of propane room air conditioner under cross-conditions based on transfer learning.
- Identifiant de la fiche : 30035264
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 189
- Date d'édition : 09/2026
- DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2026.107011
Liens
Voir d'autres articles du même numéro (30)
Voir la source
Indexation
-
Charge des groupes frigorifiques.
- Auteurs : NERI P.
- Date : 1993
- Langues : Italien
- Source : Industria & Formazione - vol. 17 - n. 5
Voir la fiche
-
Regelungstechnische Optimierung von Kälteanlage...
- Date : 06/01/2006
- Langues : Allemand
- Source : CCI.Print - vol. 40 - n. 1
- Formats : PDF
Voir la fiche
-
Richtige Auslegung und optimaler Einsatz von Kä...
- Auteurs : MÖLLER R.
- Date : 07/2001
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 37 - n. 7
Voir la fiche
-
Congélateur continu à cylindre : application à ...
- Auteurs : MARIZY C., LE BAIL A., DUPRAT J. C., REVERDY Y.
- Date : 07/1997
- Langues : Français
- Source : Rev. gén. Froid - vol. 87 - n. 975
Voir la fiche
-
Refrigerant leak detection in industrial vapor ...
- Auteurs : MTIBAA A., SESSA V., GUERASSIMOFF G.
- Date : 05/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 161
- Formats : PDF
Voir la fiche