Document IIF
Alternatives à faible PRP pour un système frigorifique commercial fonctionnant au R449A.
Low-GWP alternatives for an R-449A commercial refrigeration system.
Numéro : 1114
Auteurs : GIMÉNEZ-PRADES P., NAVARRO-ESBRÍ J., UDROIU C-M., MOTA BABILONI A.
Résumé
Current demands of the cooling sector are focused on using refrigerants with a low Global Warming Potential (GWP) in vapour compression installations. The main objectives of this paperwork arise from these needs, in which eco-friendly alternative refrigerants with a GWP under 150 are proposed and studied in an R-449A commercial refrigeration system. New refrigerant mixtures are searched from the binary and ternary combination of pure refrigerants. The best refrigerant with safety classification A1, A2L, and A2/A3, for both medium temperature (MT) and low temperature (LT) systems is obtained from this search. After their determination, the supermarket’s operation is simulated with these refrigerants. Finally, an environmental assessment is performed. The highest energy efficiency is obtained with the R-152a/R-1243zf mixture for the MT system and the R-290/R-1270 mixture for the LT system. However, the highest reduction of GHG emissions is achieved by R-290, with a reduction of 73.09% with respect to the baseline system.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Low-GWP alternatives for an R-449A commercial refrigeration system.
- Identifiant de la fiche : 30032578
- Langues : Anglais
- Sujet : Technologie
- Source : 8th IIR International Conference on Sustainability and the Cold Chain. Proceedings: June 9-11 2024
- Date d'édition : 11/06/2024
- DOI : http://dx.doi.org/10.18462/iir.iccc2024.1114
Liens
Voir d'autres communications du même compte rendu (84)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Mélanges;
Hydrocarbures;
Froid industriel, commercial et domestique : généralités - Mots-clés : R449A; GWP; Inflammabilité; R290; R1270; COP; Mélange; Efficacité énergétique
-
Energy efficiency and system performance of R-4...
- Auteurs : FERRETTO W., MOLINAROLI L., CODELLA F., CHRISTMANN J. M.
- Date : 11/06/2024
- Langues : Anglais
- Source : 8th IIR International Conference on Sustainability and the Cold Chain. Proceedings: June 9-11 2024
- Formats : PDF
Voir la fiche
-
The mixed refrigerant process and its possible ...
- Auteurs : KLIMEK L.
- Date : 10/1958
- Langues : Anglais
- Source : Application of refrigeration to the chemical industry. [Proceedings of the meetings of the] commission 6: Karlsruhe, Germany, October 20-22, 1958.
- Formats : PDF
Voir la fiche
-
Performance evaluation of various configuration...
- Auteurs : CHANG C. M., SHEN B., MUNEESHWARAN M., NAWAZ K., PICKLES E. C., HARTNETT C.
- Date : 17/07/2024
- Langues : Anglais
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
System efficiency index a tool for energy optim...
- Auteurs : BERGLÖF K.
- Date : 12/06/2015
- Langues : Anglais
- Source : Le ultime tecnologie del freddo e del condizionamento. Atti del 16° Convegno Europeo: June 12-13, 2015, Milano, Italia.
- Formats : PDF
Voir la fiche
-
Performance limit for economized cycles with co...
- Auteurs : MATHISON M. M., BRAUN J. E., GROLL E. A.
- Date : 12/07/2010
- Langues : Anglais
- Formats : PDF
Voir la fiche