Document IIF

Amélioration d'un réfrigérateur magnétique de 100 W à la température d'une salle de classe.

Improvement of 100W class room temperature magnetic refrigerator.

Auteurs : OKAMURA T., RACHI R., HIRANO N., et al.

Résumé

A rotating magnet type magnetic refrigerator was modified and its performance has been improved. The performance of the previous magnetic refrigerator was presented at the 1st IIR International Conference on Magnetic Refrigeration at Room Temperature in 2005. The system configuration was not changed but some components were modified. The new refrigerator produces a maximum cooling power of 540 W and COP of 1.8 when the temperature at the hot end of the AMR duct is 21°C and the temperature span was 0.2°C.

Documents disponibles

Format PDF

Pages : 2007-1

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Improvement of 100W class room temperature magnetic refrigerator.
  • Identifiant de la fiche : 2007-1556
  • Langues : Anglais
  • Source : 2nd International Conference on Magnetic Refrigeration at Room Temperature
  • Date d'édition : 11/04/2007

Liens


Voir d'autres communications du même compte rendu (48)
Voir le compte rendu de la conférence