Résumé
In a high-rise building,mechanical smoke venting in hallway causes a drop of the pressure. As a result,smoke can spread from the compartment of origin into the hallway. In addition,the vestibule pressurization causes the pressure difference across the vestibule door rising and the door being hard to open. To solve these promblems,this paper advances a way to supply air to the hallway on andition that the smoke exhausting rate still is code-required standard of 60m3m~2h-1,ruled in Fire Protection Code in effect and the appropriate calculation process is put forward as well. By the comparision to the data gained through field tests,it is showed that this method really is a practicable improvement to the mechanical smoke system.
Documents disponibles
Format PDF
Pages : p 598-603
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : An improvement to mechanical smoke system.
- Identifiant de la fiche : 30034089
- Langues : Anglais
- Sujet : Technologie
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Date d'édition : 09/1997
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (109)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Autres équipements de conditionnement d'air
- Mots-clés : Air extrait; Fumée; Pression; Effet hall; Sécurité; Amélioration
-
Study on the effect of air flow around high-ris...
- Auteurs : PENG X., GU W., LI H.
- Date : 24/10/2000
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High-Rise Buildings - 2000.
- Formats : PDF
Voir la fiche
-
Air crossover in rotary wheels used for air-to-...
- Auteurs : SHANG W., WAWRYK M., BESANT R. W.
- Date : 24/06/2001
- Langues : Anglais
- Source : ASHRAE Transactions. 2001 annual Meeting, Cincinnati, Ohio. Volume 107, part 2 + CD-ROM.
Voir la fiche
-
Reentrainment of flue gases and building air ex...
- Auteurs : STICKFORD G. H., SAUNDERS J. H., HESSE D. J., et al.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 annual Meeting, Honolulu, Hawaii. Volume 108, part 2 + CD-ROM.
Voir la fiche
-
Economizer control.
- Auteurs : KRAKOW K. I., ZHAO F., MUHSIN A. E.
- Date : 24/06/2000
- Langues : Anglais
- Source : ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.
Voir la fiche
-
Characterization of airflows at the exit of reg...
- Auteurs : TUTU N. K., KRISHNA C. R., BUTCHER T. A.
- Date : 2004
- Langues : Anglais
- Source : ASHRAE Transactions. 2004 Annual Meeting, Nashville, Tennessee, USA. Volume 110, part 2 + CD-ROM.
Voir la fiche