Summary
In a high-rise building,mechanical smoke venting in hallway causes a drop of the pressure. As a result,smoke can spread from the compartment of origin into the hallway. In addition,the vestibule pressurization causes the pressure difference across the vestibule door rising and the door being hard to open. To solve these promblems,this paper advances a way to supply air to the hallway on andition that the smoke exhausting rate still is code-required standard of 60m3m~2h-1,ruled in Fire Protection Code in effect and the appropriate calculation process is put forward as well. By the comparision to the data gained through field tests,it is showed that this method really is a practicable improvement to the mechanical smoke system.
Available documents
Format PDF
Pages: p 598-603
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: An improvement to mechanical smoke system.
- Record ID : 30034089
- Languages: English
- Subject: Technology
- Source: International Symposium on Air Conditioning in High Rise Buildings - 1997
- Publication date: 1997/09
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (109)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Exhaust air; Smoke; Pressure; Hall effect; Safety; Enhancement
-
Reentrainment of flue gases and building air ex...
- Author(s) : STICKFORD G. H., SAUNDERS J. H., HESSE D. J., et al.
- Date : 2002
- Languages : English
- Source: ASHRAE Transactions. 2002 annual Meeting, Honolulu, Hawaii. Volume 108, part 2 + CD-ROM.
View record
-
Energy savings potential of energy recovery ven...
- Author(s) : FREUND S., KLEIN S. A., REINDL D. T.
- Date : 2004
- Languages : English
- Source: ASHRAE Transactions. 2004 Winter Meeting. Volume 110, part 1 + CD-ROM.
View record
-
Air crossover in rotary wheels used for air-to-...
- Author(s) : SHANG W., WAWRYK M., BESANT R. W.
- Date : 2001/06/24
- Languages : English
- Source: ASHRAE Transactions. 2001 annual Meeting, Cincinnati, Ohio. Volume 107, part 2 + CD-ROM.
View record
-
Study on the effect of air flow around high-ris...
- Author(s) : PENG X., GU W., LI H.
- Date : 2000/10/24
- Languages : English
- Source: International Symposium on Air Conditioning in High-Rise Buildings - 2000.
- Formats : PDF
View record
-
A control system that prevents air from enterin...
- Author(s) : SEEM J. E., HOUSE J. M.
- Date : 1996/09
- Languages : English
View record