Document IIF
Analyse comparative d'un régénérateur par distillation membranaire sous vide et d’un régénérateur traditionnel dans un système de conditionnement d’air à déshydratant liquide.
Comparative analysis of vacuum membrane distillation regenerator and traditional regenerator in liquid desiccant air conditioning system.
Résumé
In order to solve the problem of poor regeneration performance of the solar solution dehumidification air conditioning regeneration system under high temperature and high humidity weather conditions. In this paper, a novel vacuum membrane distillation (VMD) solution regeneration method was proposed for a solution desiccant air conditioning system, and a theoretical study of this novel
regenerator is performed. Through the analysis of heat and mass transfer, the mathematical model of VMD regeneration is established, and the mathematical model is verified by experiments. The results indicated that VMD regenerator not only could increase the regenerate rate, but also could exhibit higher energy utilization efficiency. At the same concentration, the VMD regenerator has a higher regeneration performance, and the regeneration rate is 1.6-2.4 times that of the internal heat type regenerator,and the 4.5-6 times that of the adiabatic regenerator.
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparative analysis of vacuum membrane distillation regenerator and traditional regenerator in liquid desiccant air conditioning system.
- Identifiant de la fiche : 30026789
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.1459
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
Indexation
-
Modeling of a flat plate membrane-distillation ...
- Auteurs : RATTNER A. S., NAGAVARAPU A. K., GARIMELLA S., et al.
- Date : 07/2011
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 54 - n. 15-16
Voir la fiche
-
Experimental study of a membrane-based dehumidi...
- Auteurs : CHEN Z., ZHU J., BAI H., et al.
- Date : 25/03/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 115
Voir la fiche
-
Méthodes de régénération pour un système de con...
- Auteurs : LI H., ZHANG T., CONG L., et al.
- Date : 11/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 284
- Formats : PDF
Voir la fiche
-
Performance analysis of vacuum membrane distill...
- Auteurs : ZHOU J., ZHANG X., SU W., et al.
- Date : 06/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 102
- Formats : PDF
Voir la fiche
-
Performance analysis of a new solar coupling re...
- Auteurs : CHENG Q., ZHANG X.
- Date : 02/03/2014
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Formats : PDF
Voir la fiche