Analyse comparative d'un tube capillaire et d'un détendeur électronique dans un réfrigérateur domestique.

Comparative analysis between a capillary tube and an electronic expansion valve in a household refrigerator.

Résumé

This study compares the performance characteristics of a household refrigerator equipped with an Electronic Expansion Valve (EEV) with those with a capillary tube. A 513-liter top-mount refrigerator, originally equipped with a capillary tube, was retrofitted with a pulse width modulated expansion valve and extensively tested. Comparative analyses were performed based on standardized pull-down and energy consumption tests, carried out at three ambient temperatures (18, 32 and 43°C) and with three compressor speeds (2000, 3600 and 4500 rpm). It was shown that the EEV system showed better performance in terms of energy consumption, as compared with the capillary tube system, only at high cooling loads (ambient temperature of 43°C) and at low cooling capacities (compressor speed of 2000 rpm). For a wide range of operating conditions the pull-down times of both systems were kept within a difference band of plus or minus 3%.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Comparative analysis between a capillary tube and an electronic expansion valve in a household refrigerator.
  • Identifiant de la fiche : 2007-1624
  • Langues : Anglais
  • Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
  • Date d'édition : 17/07/2006

Liens


Voir d'autres communications du même compte rendu (157)
Voir le compte rendu de la conférence