Document IIF
Analyse comparative de processus d'absorption à pression et à température constantes pour un réfrigérateur solaire intermittent.
Comparative analysis between constant pressure and constant temperature absorption processes for an intermittent solar refrigerator.
Auteurs : SHAARAWI M. A. I. el-, SAID S. A. M., SIDDIQUI M. U.
Type d'article : Article, Article de la RIF
Résumé
This paper presents a detailed comparative analysis between constant pressure and constant temperature aqua-ammonia absorption processes for an intermittent solar refrigerator. The results of the analysis indicate that constant pressure processes results in as high as 20% increase in coefficient of performance compared to constant temperature processes. Also, the results indicate that there is a critical temperature below which both the constant pressure and constant temperature processes exhibit the same performance. Furthermore, it has been observed that the optimum generator temperature for constant pressure processes is approximately 12% higher than constant temperature processes. Finally, the effect of maintaining a constant temperature or constant pressure absorption processes on the heat duties of both, the absorber and the evaporator, is addressed in the paper.
Documents disponibles
Format PDF
Pages : 103-112
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparative analysis between constant pressure and constant temperature absorption processes for an intermittent solar refrigerator.
- Identifiant de la fiche : 30011084
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 41
- Date d'édition : 05/2014
Liens
Voir d'autres articles du même numéro (20)
Voir la source
-
Design and simulation of an absorption diffusio...
- Auteurs : CHAOUACHI B., GABSI S.
- Date : 2007
- Langues : Anglais
- Source : Am. J. appl. Sci. - vol. 4 - n. 2
Voir la fiche
-
Three-dimensional evaporation process in aqua-a...
- Auteurs : KOUREMENOS D. A., STEGOUSAGIA A., ANTONOPOULOS K. A.
- Date : 01/1994
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 17 - n. 1
- Formats : PDF
Voir la fiche
-
Evaluation des diagrammes enthalpique pour les ...
- Auteurs : TAKEI T., SAITO K., KAWAI S.
- Date : 1995
- Langues : Japonais
- Source : Trans. JAR - vol. 12 - n. 1
Voir la fiche
-
POSSIBILITES D'UTILISER L'ENERGIE SOLAIRE POUR ...
- Auteurs : ZALEWSKI W.
- Date : 1981
- Langues : Polonais
- Source : Chlodnictwo - vol. 16 - n. 7-8
Voir la fiche
-
ETUDE DES PERFORMANCES D'UN REFRIGERATEUR SOLAI...
- Auteurs : DURSUNOV N. C.
- Date : 1981
- Langues : Russe
- Source : Geliotehnika - n. 3
Voir la fiche