Analyse de l'écoulement d'air dans une pièce à grandeur nature avec ventilation par jet non isotherme employant des techniques de pistage par vélocimétrie des particules.
Analysis of airflow in a full-scale room with non-isothermal jet ventilation using PTV techniques.
Résumé
Draft and non-uniform fresh air distribution are common problems in winter ventilation, especially for large animal buildings. Thermal-based anemometers have difficulties in accurately measuring non-isothermal and low-speed indoor airflow. A new technology, particle tracking velocimetry (PTV), which uses particles and their images to study indoor airflow, can overcome the traditional limitations in indoor airflow measurement. A PTV system was used to characterize indoor airflow in a full-scale ventilated room under nonisothermal ventilation conditions. Non-isothermal mild weather and winter ventilation conditions were simulated to analyze their effects on indoor airflow and air velocities in animal occupied zones and human breathing zones. It is found that winter ventilation created a totally reversed rotating airflow pattern. Air velocities in the animal occupied zone increased substantially compared with the corresponding isothermal ventilation conditions. Winter ventilation strategies for improvement of airflow distribution were studied: (1) increasing inlet air velocity; (2) increasing inlet air jet momentum by use of air recirculation devices; and (3) decreasing ventilation temperature difference.
Détails
- Titre original : Analysis of airflow in a full-scale room with non-isothermal jet ventilation using PTV techniques.
- Identifiant de la fiche : 2009-0795
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
- Date d'édition : 27/01/2007
Liens
Voir d'autres communications du même compte rendu (17)
Voir le compte rendu de la conférence
Indexation
-
RECHERCHES SUR L'ECOULEMENT DE L'AIR AMBIANT DA...
- Auteurs : SODEC F., WECK F.
- Date : 1981
- Langues : Allemand
- Source : Klima Kälte Heiz. - vol. 9 - n. 12
Voir la fiche
-
Application of natural ventilation in cattle ba...
- Auteurs : MÜLLER H. J., MÖLLER B.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche
-
An individually ventilated caging system for la...
- Auteurs : MAGHIRANG R. G., RISKOWSKI G. L., HARRISON P. C., GONYOU H. W., SEBEK L., MCKEE J.
- Date : 1994
- Langues : Anglais
- Source : ASHRAE Transactions 1994.
Voir la fiche
-
SYSTEME DE CONDITIONNEMENT D'AIR POUR LES INSTA...
- Auteurs : KITAMURA S.
- Date : 1986
- Langues : Japonais
- Source : Refrigeration - vol. 61 - n. 706
Voir la fiche
-
Ventilation effectiveness criteria and measurem...
- Auteurs : JEREZ S. B., ZHANG Y., WANG X.
- Date : 27/01/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
Voir la fiche