Summary
Draft and non-uniform fresh air distribution are common problems in winter ventilation, especially for large animal buildings. Thermal-based anemometers have difficulties in accurately measuring non-isothermal and low-speed indoor airflow. A new technology, particle tracking velocimetry (PTV), which uses particles and their images to study indoor airflow, can overcome the traditional limitations in indoor airflow measurement. A PTV system was used to characterize indoor airflow in a full-scale ventilated room under nonisothermal ventilation conditions. Non-isothermal mild weather and winter ventilation conditions were simulated to analyze their effects on indoor airflow and air velocities in animal occupied zones and human breathing zones. It is found that winter ventilation created a totally reversed rotating airflow pattern. Air velocities in the animal occupied zone increased substantially compared with the corresponding isothermal ventilation conditions. Winter ventilation strategies for improvement of airflow distribution were studied: (1) increasing inlet air velocity; (2) increasing inlet air jet momentum by use of air recirculation devices; and (3) decreasing ventilation temperature difference.
Details
- Original title: Analysis of airflow in a full-scale room with non-isothermal jet ventilation using PTV techniques.
- Record ID : 2009-0795
- Languages: English
- Source: ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
- Publication date: 2007/01/27
Links
See other articles from the proceedings (17)
See the conference proceedings
Indexing
- Themes: Air conditioning in laboratories and industry
- Keywords: Velocity (fluids, gases); Rearing house; Measurement; Ventilation; Animal; Air; Process; Flow; Air conditioning
-
Application of natural ventilation in cattle ba...
- Author(s) : MÜLLER H. J., MÖLLER B.
- Date : 2007/06/10
- Languages : English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
View record
-
Evaluation of the environmental conditions in a...
- Author(s) : YOSHIDA K., HACHISU H., YOSHIDA J. A., SHUMIYA S.
- Date : 1994
- Languages : English
- Source: ASHRAE Transactions 1994.
View record
-
An individually ventilated caging system for la...
- Author(s) : MAGHIRANG R. G., RISKOWSKI G. L., HARRISON P. C., GONYOU H. W., SEBEK L., MCKEE J.
- Date : 1994
- Languages : English
- Source: ASHRAE Transactions 1994.
View record
-
Ventilation effectiveness criteria and measurem...
- Author(s) : JEREZ S. B., ZHANG Y., WANG X.
- Date : 2007/01/27
- Languages : English
- Source: ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
View record
-
AIR CONDITIONING SYSTEM FOR ANIMAL EXPERIMENTAL...
- Author(s) : KITAMURA S.
- Date : 1986
- Languages : Japanese
- Source: Refrigeration - vol. 61 - n. 706
View record