Analyse de la consommation énergétique des conditionneurs d’air individuels : approche utilisant des données opérationnelles individuelles à partir de mesures effectuées sur le terrain.
Analysis of energy consumption of room air conditioners: An approach using individual operation data from field measurements.
Auteurs : KINDAICHI S., NISHINA D., MURAKAWA S., et al.
Type d'article : Article
Résumé
Room air conditioners (RACs) are heating/cooling appliances used widely in residential buildings. RAC seasonal or annual performance is strongly influenced by the user’s operation schedule and by mechanical efficiency. In this paper, we address the energy consumption of RACs under different heat-load conditions and schedules. Individual operations were extracted from a series of energy consumption data for 87 RAC units. Individual operation data were divided into two groups, mild- and severe-load conditions, whose outdoor temperatures differed by 5 °C. Mild-load conditions tended to result in shorter individual operation durations than did severe-load conditions, suggesting a difference in user behavior. When individual operation durations were reduced by 20%, average energy reductions of 40% were observed. Part of this reduction resulted from duration reduction; the rest came from changes in RAC physical efficiency, which depends on outdoor temperature and heating/cooling load. The time-reduction effect exceeded the physical-efficiency effect when individual operation durations were shortened by >20% during heating, or by >26% during cooling.
Détails
- Titre original : Analysis of energy consumption of room air conditioners: An approach using individual operation data from field measurements.
- Identifiant de la fiche : 30020743
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 112
- Date d'édition : 05/02/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.10.017
Liens
Voir d'autres articles du même numéro (39)
Voir la source
Indexation
-
Eficiencia energética de edificios.
- Date : 10/2003
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - n. 352
Voir la fiche
-
Arrêté du 3 mai 2007 relatif au diagnostic de p...
- Date : 17/05/2007
- Langues : Français
- Source : J. off. Union eur., L - n. 114
Voir la fiche
-
DOE sets 12 SEER minimum standard.
- Auteurs : MAZURKIEWICZ G.
- Date : 04/06/2002
- Langues : Anglais
- Source : Air Cond. Heat. Refrig. News/achrnews.com - 4 p.
Voir la fiche
-
Seasonal applicability of refrigerant release t...
- Auteurs : WANG B., JI W., HAN L., et al.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
TRANSIENT RESPONSE OF AIR CONDITIONERS. A QUALI...
- Auteurs : MURPHY W. E., GOLDSCHMIDT V. W.
- Date : 1984
- Langues : Anglais
Voir la fiche