Document IIF
Analyse de la distribution de la vitesse de l'air dans la conduite d'air neuf d'un meuble frigorifique de vente grâce à la technique de vélocimétrie par visualisation des particules.
Air velocity distribution analysis in the air duct of a display cabinet by PIV technique.
Numéro : pap. ID: 546
Auteurs : MARINETTI S., CAVAZZINI G., FEDELE L., et al.
Résumé
This work is aimed at presenting an analysis, by stereoscopic particle image velocimetry (PIV) technique, of the air speed distribution inside the cooling duct of a display cabinet and its effect on the heat exchange efficiency. A simplified configuration of the duct, in which the air is forced through the evaporator by a fan, is tested. 3D flow fields, upstream and downstream the evaporator, are determined by PIV performed on three planes containing the mainstream velocity vectors and placed at different heights. Measurements are carried out at the maximum fan rotation rate. The analysis of the air flow distribution at the inlet and outlet of the evaporator shows the capabilities of the PIV technique to highlight insufficiently loaded sections of the evaporator and to estimate the energy transfer efficiency. These results are compared with those of an ideal configuration, in which the air flow rate is uniformly distributed at the evaporator entrance.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Air velocity distribution analysis in the air duct of a display cabinet by PIV technique.
- Identifiant de la fiche : 30001978
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
- Voir aussi : Air velocity distribution analysis in the air duct of a display cabinet by PIV technique.
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
-
Air velocity distribution analysis in the air d...
- Auteurs : MARINETTI S., CAVAZZINI G., FEDELE L., et al.
- Date : 12/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 8
- Formats : PDF
Voir la fiche
-
Novel energy efficiency assessement approach of...
- Auteurs : BRADY N.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
New type of energy efficient heat exchanger for...
- Auteurs : HAGLUND STIGNOR C., MARTIN SANTANA S., LARSSON O.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
New type of energy efficient heat exchanger for...
- Auteurs : HAGLUND STIGNOR C., TILJANDER P., LINDBERG U., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
Energy-efficient flat-tube heat exchangers for ...
- Auteurs : HAGLUND STIGNOR C., SUNDÉN B., FAHLÉN P.
- Date : 09/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 6
- Formats : PDF
Voir la fiche