Résumé
The processes of mass recovery and heat recovery in a silica gel-water solar adsorption air-conditioning system were investigated. In this system, a heat pipe type evaporator without vacuum valves was designed, and water was employed as the heat pipe working medium instead of methanol. A capillary tube was installed between two adsorber vacuum chambers for the balance of the refrigerant. Moreover, the influence of the hot water temperature on the mass recovery and the influence of the heat recovery on COP were explored. In addition, the optimization of the heat recovery process was discussed. The results show that the cooling capacity was 15.3 kW and the COP was 0.50 when the inlet temperature of hot water, inlet temperature of cooling water, outlet temperature of chilled water, mass recovery time, and heat recovery time were 79.2, 29.6, and 14.9°C, 90s, and 30s, respectively. When they were 64.8, 29.6, and 15.2°C, 180s, and 30s, respectively, the cooling capacity was 7.5 kW and the COP was 0.36.
Documents disponibles
Format PDF
Pages : pp. 7-13
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2010-1544
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 31 - n. 4
- Date d'édition : 08/2010
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2010.04.007
Liens
Voir d'autres articles du même numéro (7)
Voir la source
Indexation
-
Experimental testing of adsorption chiller with...
- Auteurs : THU K., NG K. C., SHARKAWY I. I. el-, et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Experimental verification of an absorption chil...
- Auteurs : PATNAIK V.
- Date : 2004
- Langues : Anglais
- Source : ASHRAE Transactions. 2004 Winter Meeting. Volume 110, part 1 + CD-ROM.
Voir la fiche
-
Performance improvement of NH3–H
- Auteurs : WIRTZ M., STUTZ B., PHAN H. T., BOUDÉHENN F.
- Date : 12/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 144
- Formats : PDF
Voir la fiche
-
Performance prediction of a two-bed solar adsor...
- Auteurs : UL QADIR N., SAID S. A. M., BEN-MANSOUR R.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche
-
Experimental study on a continuous adsorption w...
- Auteurs : LIU Y. L., WANG R. Z., XIA Z. Z.
- Date : 03/2005
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 28 - n. 2
- Formats : PDF
Voir la fiche