Analyse des données sur la consommation d'énergie électrique dans les immeubles à l'aide d'une méthode améliorée utilisant les degrés-jours de refroidissement.
Analysis of building electric energy consumption data using an improved cooling degree day method.
Résumé
In cases where a quick insight into the operation of an HVAC system is more important than accuracy, cooling degree days can be used for monitoring electric energy consumption dependent on meteorological conditions. Cooling degree days are calculated from differences between outdoor temperatures above the base temperature and the base temperature itself, therefore containing both climate and building information. The difficulties in applying this method are the determination of base temperature and choosing a procedure for calculating degree days, which vary depending on the resolution of the weather data used. In addition, the cooling degree method has a major flaw, i.e. it considers only a linear dependence between cooling energy consumption and sensible cooling load, thereby ignoring latent loads, which become more significant at higher outdoor temperatures. In this article an analysis of real electric energy consumption data using the cooling degree method and an improved method derived from it that includes latent loads, as well as a comparison between them, are shown. Both methods are applied several times to metered data, each time with a different combination of a method for determining base temperature and a degree day calculation technique.
Documents disponibles
Format PDF
Pages : 107-114
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Analysis of building electric energy consumption data using an improved cooling degree day method.
- Identifiant de la fiche : 30004894
- Langues : Anglais
- Source : Strojniski vestnik - Journal of mechanical Engineering - vol. 58 - n. 2
- Date d'édition : 02/2012
Liens
Voir la source
Indexation
-
THE OTTV AND DEGREE-DAYS FOR ESTIMATING THE ENE...
- Auteurs : CHOU S. K., BONG T. Y., LEE Y. K.
- Date : 1986
- Langues : Anglais
- Source : AIRAH J. - vol. 40 - n. 5
Voir la fiche
-
On the Impact of Climate Change on Building Ene...
- Auteurs : CAMPAGNA L. M., FIORITO F.
- Date : 01/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 1
- Formats : PDF
Voir la fiche
-
AN ANALYSIS OF OFFICE EQUIPMENT LOAD FACTORS.
- Auteurs : WILKINS C. K., KOSONEN R., LAINE T.
- Date : 09/1991
- Langues : Anglais
- Source : ASHRAE Journal - vol. 33 - n. 9
Voir la fiche
-
An improved use of cooling degree-days for anal...
- Auteurs : DAY A. R.
- Date : 06/2005
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 26 - n. 2
Voir la fiche
-
Analyse expérimentale et énergétique de l'envir...
- Auteurs : HUANG C., LI M., ZOU Z., et al.
- Date : 12/2000
- Langues : Chinois
- Source : HV & AC - vol. 30 - n. 137
Voir la fiche