Document IIF
Analyse des risques liés à la manipulation de frigorigènes inflammables lors des activités d'entretien et de maintenance.
Risk analysis of flammable refrigerant handling during service and maintenance activities.
Numéro : pap. ID: 631
Auteurs : COLBOURNE D.
Résumé
Flammability risk of hydrocarbon refrigerants in refrigeration and air considering systems has only been addressed to a limited extent for refrigerant handling activates during service and maintenance of systems to such an extent. This study investigates these stages in detail. Typical procedures are broken down into discrete tasks: preparation of the working area, confirmation of correct tools, initial system checks, accessing the system, removing refrigerant, breaking into the system, carrying out repair, sealing the system, charging the system, strength pressure checking, closing the system, leak tightness checking and final system checks. Throughout, errors may arise due to use of incorrect equipment/tools and deviation from instructions. Event tree analysis is used to identify the combinations of sequence of events that may lead to a release of refrigerant and an active source of ignition that could result in ignition and eventually the probability of ignition and severity of consequences.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Risk analysis of flammable refrigerant handling during service and maintenance activities.
- Identifiant de la fiche : 30002232
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Hydrocarbures
- Mots-clés : Maintenance; Manutention; Inflammabilité; Hydrocarbure; Fuite; Frigorigène
-
Characterisation of a leak of flammable refrige...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
A risk assessment for leakages of flammable ref...
- Auteurs : NAGAOSA R., AUTE V. C., RADERMACHER R.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Research on the flammability hazards of an air ...
- Auteurs : ZHANG W., YANG Z., LI J., et al.
- Date : 08/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 5
- Formats : PDF
Voir la fiche
-
Development of R290 transport refrigeration sys...
- Auteurs : COLBOURNE D., SOLOMON P., WILSON R., et al.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
R290 concentrations arising from leaks in comme...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche