Une évaluation des risques liés aux fuites de frigorigènes inflammables dans un espace fermé.
A risk assessment for leakages of flammable refrigerants into a closed space.
Numéro : pap. 2240
Auteurs : NAGAOSA R., AUTE V. C., RADERMACHER R.
Résumé
This study proposes a procedure for a risk analysis for leakages of flammable refrigerants into a poorly ventilated three-dimensional space. It also presents several test cases of risk analyses on flammability and ignitions to a leaked refrigerant. Concentration of a leaked flammable refrigerant at a leakage window, Cin, is determined by mass balance, providing information on the capacity of an air-refrigerant mixture, and the leakage rate. Five flammable refrigerants, 2,3,3,3-tetrafluoropropene (R-1234yf), difluoromethane (R-32), 1,1-difluoroethane (R-152a), propane (R-290), and ammonia (R-717) have been used to analyze risk of ignitions and flammability. A computational fluid mechanics (CFD) technique has been applied to the present risk analyses, and temporal development of velocity, concentration, and temperature profiles of an air-refrigerant mixture in a three-dimensional space are computed. The obtained concentration profiles are compared with the lower flammability limits to analyze detailed risk of ignitions and flammability. The results of this study demonstrate that risk of ignitions can be investigated successfully based on the current CFD technique. This study furthermore shows that risk of ignitions and flammability is different depending on the flammability characteristics of each refrigerant. This study proposes an indicator, the Safety Index, to evaluate risk of ignitions in individual cases easily as screening of flammability without performing threedimensional calculations based on a CFD technique.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A risk assessment for leakages of flammable refrigerants into a closed space.
- Identifiant de la fiche : 30006662
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (195)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Ammoniac;
Hydrocarbures - Mots-clés : R1234yf; Ammoniac; R32; R290; R152a; Prévision; Inflammabilité; Fuite; Frigorigène
-
Research on the field strength characteristics ...
- Auteurs : LI Y., YANG J., WU Y., LIU Y., ZHOU P., YAN Y., HAN X.
- Date : 09/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 153
- Formats : PDF
Voir la fiche
-
Comparativa de prestaciones de una bomba de cal...
- Auteurs : SÁNCHEZ-MORENO-GINER L., LÓPEZ-JUÁREZ E., GONZÁLVEZ-MACIÁ J.
- Date : 19/06/2018
- Langues : Espagnol
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche
-
Combustion suppression effect of additives for ...
- Auteurs : HIGASHI T., DANG C., HIHARA E., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Computational fluid dynamics analysis of flamma...
- Auteurs : ZHANG S., CHEN G., LI Z., FANG J.
- Date : 02/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 134
- Formats : PDF
Voir la fiche
-
Research of refrigerant substitution, new refri...
- Auteurs : NING J., ZHENG T.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche