Recommandé par l'IIF / Document IIF
Analyse énergétique de l’ouverture des portes de meubles frigorifiques de vente verticaux à portes vitrées
Energy analysis of door openings in vertical refrigerated display cabinets with glass doors.
Numéro : 184
Auteurs : VALLÉE C., MAHMOUD A. M., ADHIKARI S.
Résumé
In order to understand the energy consumption contribution of the door openings in a refrigerated display cabinet, a simple reduced order model was developed, assuming a closed-door base load to which the energy consumption of each door opening is added and consists of a constant amount of energy as function of the number of door openings and a second part which is a function of the opening duration. A vertical refrigerated display cabinet with incorporated condensing unit and two glass doors was tested in a climate room at the design conditions of 25°C and 60% relative humidity. A series of tests was performed with various door opening times and frequencies kept constant over 12 hours. The test results confirm the model assumptions and indicate that the constant energy consumption part attributed to the door opening dynamics corresponds to the energy loss during a door opening of 1.9 seconds.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy analysis of door openings in vertical refrigerated display cabinets with glass doors.
- Identifiant de la fiche : 30031306
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0184
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
A2L and A3 refrigerant testing for commercial r...
- Auteurs : WANG X.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Doored display fridges: an investigation into t...
- Auteurs : SARNO D.
- Date : 11/04/2022
- Langues : Anglais
- Source : 7th IIR International Conference on Sustainability and the Cold Chain (Online). Proceedings: April 11-13 2022
- Formats : PDF
Voir la fiche
-
Mediciones experimentales del comportamiento de...
- Auteurs : BLANCO CASTRO J., GUILLEM ARMELA J.
- Date : 22/02/2012
- Langues : Espagnol
- Source : CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
Voir la fiche
-
Vertical display cabinets with doors: influence...
- Auteurs : LINDBERG U., AXELL M., FAHLÉN P.
- Date : 13/06/2010
- Langues : Anglais
- Source : IIR/Eurotherm sustainable refrigeration and heat pump technology conference. Proceedings of the Eurotherm Seminar No. 88, Stockholm, Sweden, June 13-16, 2010.
- Formats : PDF
Voir la fiche
-
Influence of door openings on temperature fluct...
- Auteurs : LI X., ZHU D. S., WANG N., et al.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche