Document IIF
Influence de la stratégie de régulation du compresseur sur l’efficacité énergétique et la température des produits des comptoirs de vente professionnels.
Influence of compressor control strategy on energy efficiency and product temperature for professional counter cabinets.
Numéro : pap. 1248
Auteurs : JENSEN J. K., KAERN M. R., PEDERSEN P. H., et al.
Résumé
EU regulations 2015/1095 and 2015/1094 of 5 May 2015 have been implemented for professional refrigerated counters along with the test standard EN 16825. These regulations rates most current counters as class C or D and consequently there is an ongoing development to construct top level counters (A or above). Apart from improving the cabinet construction and improving the condenser and evaporator design, advanced compressor control strategies could be part of the solution. This could be either variable speed drive (VSD) or adaptive energy optimization (AEO). Both control strategies may improve the energy efficiency but may also affect the temperature fluctuations of the stored goods. The influence of VSD and AEO was investigated using a validated dynamic model of a professional refrigerated counter using R290 and R600a. The influence was investigated according to the EN 16825 test conditions. Both VSD and AEO yield significant energy savings compared to ON-OFF control. A more constant product temperature was achieved by VSD control, while the product temperature fluctuates slightly more when applying AEO control.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Influence of compressor control strategy on energy efficiency and product temperature for professional counter cabinets.
- Identifiant de la fiche : 30023643
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Date d'édition : 18/06/2018
- DOI : http://dx.doi.org/10.18462/iir.gl.2018.1248
Liens
Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence
Indexation
-
Variable speed compressors with HCs refrigerant...
- Auteurs : BASSI M., CASAMASSIMA R.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
EFFICACITE DE L'ECHANGE DE CHALEUR ENTRE CONDUI...
- Auteurs : ANDRJUSCENKO A. G., BACURIN O. A.
- Date : 1990
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 6
Voir la fiche
-
Energy analysis of door openings in vertical re...
- Auteurs : VALLÉE C., MAHMOUD A. M., ADHIKARI S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Building better supermarkets for the world.
- Auteurs : FISCHER J., DANFOSS
- Date : 06/2023
- Langues : Anglais
Voir la fiche
-
Performance of integral hydrocarbon cabinets fo...
- Auteurs : SUAMIR I., TASSOU S. A., ARROWSMTH P., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche