Document IIF

Analyse exergétique d’un cryorefroidisseur à cycle de Brayton inversé pour différentes charges frigorifiques à 65K pour des câbles supraconducteurs à haute température.

Exergetic analysis of reverse brayton cryocooler for different cooling loads at 65 K for HTS cables.

Numéro : pap. n. 27

Auteurs : DHILLON A. K., DUTTA R., GHOSH P.

Résumé

Cryocoolers with cooling capacity of 1-5 kW at 65 K are required to operate the high-temperature superconductors (HTS) power cables. In this paper, an RBC for cooling of HTS cables is analysed and optimized using Aspen HYSYS V8.6®. Exergy approach has been adopted to analyse the RBC. The optimization problem developed based on exergy efficiency maximization. Three load conditions of 1, 3 and 5 kW at 65 K with neon and helium as working fluids have been considered. Additionally, the effects of variation of operating parameters on the performance of the systems were identified, and the effects of turbine and compressor efficiencies and heat exchanger effectiveness have been studied. As a result, the cycle configurations with optimum process parameters have been identified and presented in this work. The conclusions of this article will be helpful in deciding modification in basic different cooling loads.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Exergetic analysis of reverse brayton cryocooler for different cooling loads at 65 K for HTS cables.
  • Identifiant de la fiche : 30021703
  • Langues : Anglais
  • Source : Cryogenics 2017. Proceedings of the 14th IIR International Conference: Dresden, Germany, Mai 15-19, 2017.
  • Date d'édition : 15/05/2017
  • DOI : http://dx.doi.org/10.18462/iir.cryo.2017.0027

Liens


Voir d'autres communications du même compte rendu (71)
Voir le compte rendu de la conférence