Document IIF
Analyse théorique de l’échangeur de chaleur interne dans les systèmes de pompes à chaleur transcritiques au CO2 et sa vérification expérimentale.
Theoretical analysis of internal heat exchanger in transcritical CO2 heat pump systems and its experimental verification.
Résumé
Many studies have investigated the effect of internal heat exchanger (IHX) on the transcritical CO2 heat pump (TCHP) system. However, little information is available regarding the length of IHX under various water temperature conditions. In this paper, the theoretical model was established to compare the heating performance with and without IHX. A prototype TCHP test-rig was conducted to validate the model, and the experimental results showed a good agreement. The results show that the effect of IHX on the coefficient of performance (COP) is related with inlet water temperature. The IHX is beneficial for the COP with higher temperature 40 °C. Meanwhile, the optimal discharge pressure is reduced by more than 1 MPa with the IHX length increasing from 0 m to 4 m. Although the longer length is profitable, the discharge temperature will tend to rise 25 °C and easily exceed 145 °C when the ambient temperature depresses to 2 °C. Therefore, the length in this paper is recommended to be approximately 2.5 m considering the conflict between the discharge pressure and discharge temperature.
Documents disponibles
Format PDF
Pages : 506-516
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Theoretical analysis of internal heat exchanger in transcritical CO2 heat pump systems and its experimental verification.
- Identifiant de la fiche : 30027016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Date d'édition : 10/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.05.022
Liens
Voir d'autres articles du même numéro (54)
Voir la source
Indexation
-
Étude expérimentale des caractéristiques de per...
- Auteurs : JU X., CUI X.
- Date : 06/2013
- Langues : Chinois
- Source : Refrigeration - vol. 32 - n. 2
Voir la fiche
-
Modeling and simulation of a transcritical CO2 ...
- Auteurs : SIAN R., WANG C. C.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Sensibilidad y diseño de un sistema de refriger...
- Auteurs : NGUYEN C., VEJE C., WILLATZEN M., et al.
- Date : 06/2013
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 41 - n. 459
- Formats : PDF
Voir la fiche
-
Sensitivity and design of a transcritical CO2 c...
- Auteurs : NGUYEN C., VEJE C., WILLATZEN M., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Optimal discharge pressure in transcritical CO<...
- Auteurs : YE Z., WANG Y., SONG Y., YIN X., CAO F.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche