Pression de refoulement optimale dans un chauffe-eau à pompe à chaleur au CO2 transcritique avec échangeur de chaleur interne basé sur l’analyse du pincement.
Optimal discharge pressure in transcritical CO2 heat pump water heater with internal heat exchanger based on pinch point analysis.
Résumé
In transcritical CO2 heat pump water heater, the pinch point in gas cooler and the utilization of internal heat exchanger (IHX) both have a significant impact on the optimal discharge pressure and system performance. A theoretical model was developed to investigate the effects, and the results demonstrated that when the water inlet temperature was low, the pinch point prevented the gas cooler outlet temperature from approaching the water inlet temperature at low discharge pressure, which impaired the coefficient of performance (COP). The application of IHX could reduce the gas cooler outlet temperature by 4.9 °C when the water inlet temperature was 10 °C and the discharge pressure was 8.5 MPa. In this condition, combining with the subcooling effect of IHX, the COP was accordingly improved by 26.3%. Regardless of the working condition, using IHX lowered the optimal discharge pressure and enhanced corresponding optimal COP. In addition, parametric analyses were conducted, and the results indicated that the augment of water outlet temperature and ambient temperature resulted in the rise of optimal discharge pressure. The increase of water inlet temperature mostly enlarged the optimal discharge pressure as well. Overall, the optimal discharge pressure varied within a range of 8.53 MPa to 13.38 MPa. The reduction of optimal discharge pressure caused by using IHX intensified with the increase of water inlet and outlet temperature. Nevertheless, the effect of ambient temperature was various depending on the working condition. The reduction of optimal discharge could be up to 1.18 MPa when the effectiveness of IHX was 0.6.
Documents disponibles
Format PDF
Pages : 12-20
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Optimal discharge pressure in transcritical CO2 heat pump water heater with internal heat exchanger based on pinch point analysis.
- Identifiant de la fiche : 30027692
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Date d'édition : 10/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.06.003
Liens
Voir d'autres articles du même numéro (50)
Voir la source
Indexation
-
100℃ Hot Water Supplied by CO2 Trans...
- Auteurs : HUANG R., HU B., GE T. S., EIKEVIK T. M.
- Date : 13/06/2022
- Langues : Anglais
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
Voir la fiche
-
Transcritical carbon dioxide microchannel heat ...
- Auteurs : GOODMAN C., FRONK B., GARIMELLA S.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Theoretical analysis of internal heat exchanger...
- Auteurs : CAO F., WANG Y., YE Z.
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
Modeling and simulation of a transcritical CO2 ...
- Auteurs : SIAN R., WANG C. C.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Improvement of the performance of a transcritic...
- Auteurs : GARCIA CASCALES J. R., OTON MARTINEZ R. A., ILLÁN GÓMEZ F., SÁNCHEZ-VELASCO F. J., SENA CUEVAS V.
- Date : 11/11/2020
- Langues : Anglais
- Source : X Congreso Ibérico y VIII Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2020.
- Formats : PDF
Voir la fiche