Analyse thermodynamique des pompes à chaleur aérothermiques à compression mono-étagée avec différents modes de récupération pour une élévation de température importante.

Thermodynamic analysis of single-stage compression air-source heat pumps with different recuperation ways for large temperature lift.

Auteurs : SUN S., GUO H., GONG M.

Type d'article : Article, Article de la RIF

Résumé

Traditional single-stage compression air-source heat pumps for large heat supply temperature lift suffer tough challenges in high pressure ratio and low efficiency. In this paper, we focus on the large temperature lift heat pump water heater systems with a temperature lift of 68 K. Three binary refrigerants R1270/R1234yf, R1270/R600 and R1270/Hexane, three kinds of heat recuperation methods without recuperation, single-phase recuperation, and two-phase recuperation are adopted. System optimization is implemented by the genetic algorithm to acquire optimal operational conditions and refrigerant com- positions. Exergy analysis is used to reveal the irreversible loss distribution in systems. The sensitivity analysis of ambient temperature and heat supply temperature is conducted. The results reveal the crucial role of big temperature glide of refrigerant to decrease irreversible losses in condensation and heat recuperation. The optimal COP and volumetric heat capacity of the heat pump with two-phase heat recuperation are 6%, 70% higher than that of the traditional heat pump when the ambient temperature is 25 °C. Moreover, the heat pump with two-phase heat recuperation shows a higher COP when the heat supply temperature exceeds 72 °C and shows COP of 2.1 even the ambient temperature is -20 °C. The strong ability of the two-phase heat recuperative heat pump to enlarge the temperature lift efficiently is verified.

Documents disponibles

Format PDF

Pages : 91-102

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Thermodynamic analysis of single-stage compression air-source heat pumps with different recuperation ways for large temperature lift.
  • Identifiant de la fiche : 30027054
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 108
  • Date d'édition : 12/2019
  • DOI : http://dx.doi.org//10.1016/j.ijrefrig.2019.09.006