Document IIF
Analyse des performances des pompes à chaleur avec des mélanges zéotropes dans différentes conditions de charge.
Performance analysis of heat pumps with zeotropic mixtures at different load conditions.
Auteurs : SOGAARD KRISTENSEN A., KRUSE SORENSEN E., MADSEN C., KRISTOFERSSON J., FOROOGHI P.
Type d'article : Article de la RIF
Résumé
Heat pump cycles with zeotropic mixtures as working fluids and temperature glides on both heat sink and heat source sides are analyzed. Five binary zeotropic mixtures, selected based on previous studies in the literature, are examined. The cycles are initially optimized for each binary mixture at three different heat source temperature glides (10–30 K) and fixed heat sink temperature glide (30 K). The variation in the heating COP of the optimized designs is then computed and compared for five different part load scenarios down to 40% of the design point heating load. The design point optimization is performed for different single and double-compression cycle layouts, based on which the standard vapor compression cycle with a suction gas heat exchanger is adopted as the most economical option for the rest of the study. The part load cycle simulations demonstrate that, when the heat source temperature glide is large, two of the studied part load scenarios can lead to increased COP; these are when the reduction in the heating load is due to (1) an increase in both the heat sink (e.g. district heating water) inlet and heat source (e.g. process water) outlet temperatures, and (2) a decrease in both heat sink and source flow rates. Moreover, it is observed that different mixtures show different levels of sensitivity to a decrease in heating load. Among the studied mixtures, DME/Iso-Pentane while outperforming others in all studied cases, has the most unfavorable trend at part load, hence losing its benefit margin over other candidates.
Documents disponibles
Format PDF
Pages : 264-275
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance analysis of heat pumps with zeotropic mixtures at different load conditions.
- Identifiant de la fiche : 30030815
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Date d'édition : 01/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.09.028
Liens
Voir d'autres articles du même numéro (45)
Voir la source
Indexation
-
Experimental investigation of a heat pump tumbl...
- Auteurs : COP M., BARTA R. B., THOMAS C., HESSE U.
- Date : 02/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 158
- Formats : PDF
Voir la fiche
-
Ciclo de la bomba de calor: análisis con mezcla...
- Auteurs : ONAKA Y., MIYARA A., TSUBAKI K., et al.
- Date : 07/2010
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 38 - n. 427
- Formats : PDF
Voir la fiche
-
ANALYSE THEORIQUE DES CARACTERISTIQUES DU CYCLE...
- Auteurs : KAGAWA N., UEMATSU M., WATANABE K.
- Date : 1991
- Langues : Japonais
- Source : Trans. JAR - vol. 8 - n. 1
Voir la fiche
-
Thermodynamic analysis of single-stage compress...
- Auteurs : SUN S., GUO H., GONG M.
- Date : 12/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 108
- Formats : PDF
Voir la fiche
-
Numerical prediction of heat pump dynamic behav...
- Auteurs : SAMI S. M., ZHOU Y.
- Date : 1995
- Langues : Anglais
- Source : Int. J. Energy Res. - vol. 19
Voir la fiche