Analyses exergétiques, économiques et environnementales (3E) et optimisation multi-objectif d'un système frigorifique en cascade au CO2/NH3.
Exergetic, economic and environmental (3E) analyses, and multi-objective optimization of a CO2/NH3 cascade refrigeration system.
Auteurs : AMINYAVARI M., NAJAFI B., SHIRAZI A., et al.
Type d'article : Article
Résumé
In the present study, a CO2/NH3 cascade refrigeration system is modeled and analyzed from exergetic, economic and environmental points of view. In the next step, multi-objective optimization using genetic algorithm method is employed to achieve the optimal design parameters of the system. The exergetic efficiency and the total cost rate of the system (including the capital and maintenance costs, operational cost, and social cost of CO2 emission) are taken into account as objective functions. A set of optimal solutions is achieved and a final optimum point is then chosen using TOPSIS decision-making method. A sensitivity analysis has been performed to study the effect of variation of the unit cost of electricity on the achieved optimal solutions. While operating at the achieved optimum design, the variation of the exergy destruction of each component and the whole system due to the change in the cooling load has also been investigated. The optimization results demonstrate that for the considered plant with cooling capacity of 50 kW, the optimum design selected from the Pareto front results in exergetic efficiency of 45.89%, while it leads to the total cost rate of 0.01099 US$ s-1.
Détails
- Titre original : Exergetic, economic and environmental (3E) analyses, and multi-objective optimization of a CO2/NH3 cascade refrigeration system.
- Identifiant de la fiche : 30011000
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 65 - n. 1-2
- Date d'édition : 04/2014
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2013.12.075
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Thèmes :
Ammoniac;
CO2;
Efficacité energétique, économie d'énergie - Mots-clés : Système frigorifique; Exergie; R744; Ammoniac; Optimisation; Système en cascade; CO2
-
Theoretical analysis of a CO2-NH3 cascade refri...
- Auteurs : DOPAZO J. A., FERNÁNDEZ-SEARA J., SIERES J., et al.
- Date : 06/2009
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 29 - n. 8-9
Voir la fiche
-
Energy and environmental performance assessment...
- Auteurs : GULLO P., ELMEGAARD B., CORTELLA G.
- Date : 04/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 64
- Formats : PDF
Voir la fiche
-
A comparative study on the environmental impact...
- Auteurs : BESHR M., AUTE V., SHARMA V., et al.
- Date : 08/2015
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 56
- Formats : PDF
Voir la fiche
-
Comparación de los ciclos de refrigeración con ...
- Auteurs : ARTECONI A., BRANDONI C., DI NICOLA G., et al.
- Date : 07/2013
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 41 - n. 460
- Formats : PDF
Voir la fiche
-
Comparative analysis of various CO2 configurati...
- Auteurs : SHARMA V., FRICKE B., BANSAL P.
- Date : 10/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 46
- Formats : PDF
Voir la fiche