Document IIF
Application de prévisions « floues » de la performance des refroidisseurs d'eau à condenseur à air lors de leur fonctionnement.
Applying grey forecasting to predicting the operating energy performance of air cooled water chillers.
Résumé
Grey forecasting has found applications in finance, social science, economics, etc. However, its applications in air conditioning and refrigeration had not been reported. This article reports on a study in which a grey forecasting method was applied to predicting the operating energy performance for an air-cooled water chiller (ACWC) unit, so as to demonstrate that this forecasting approach can be applied to building Heating Ventilation and Air Conditioning (HVAC) installations. A brief introduction of the background and fundamentals of grey forecasting is firstly presented. This is followed by reporting on the application of grey forecasting to an ACWC unit installed in Northern China in order to predict its operating energy performance using the variation ratio of coefficient of performance (delta COP). The predicted delta COP values agreed well with the measured delta COP, demonstrating that grey forecasting may be used for predicting the operating energy performance of an ACWC unit with high accuracy. Finally, the potential use of grey forecasting in fault detection and diagnostics (FDD) or energy management systems (EMSs) for air-conditioning and refrigeration systems is assessed, and comparison with the prediction method based on artificial neural network (ANN) discussed.
Documents disponibles
Format PDF
Pages : 385-392
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Applying grey forecasting to predicting the operating energy performance of air cooled water chillers.
- Identifiant de la fiche : 2004-1906
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 27 - n. 4
- Date d'édition : 06/2004
Liens
Voir d'autres articles du même numéro (16)
Voir la source
Indexation
-
Efficiency improvements of air-cooled chillers ...
- Auteurs : YU F. W., CHAN K. T., CHU H. Y.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Applicability of a bifurcated bare-tube heat ex...
- Auteurs : HUANG Z., HUANG R., LING J., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Simulation of a double-effect absorber cooling ...
- Auteurs : LUDOVISI D., WOREK W. M., MECKLER M.
- Date : 07/2006
- Langues : Anglais
- Source : HVAC&R Research - vol. 12 - n. 3
Voir la fiche
-
Studio di comparazione energetica ed economica ...
- Auteurs : BOECHE A., CALLEGARI S., PASQUALE L.
- Date : 07/03/2002
- Langues : Italien
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
Voir la fiche
-
Advanced control of heat rejection airflow for ...
- Auteurs : YU F. W., CHAN K. T.
- Date : 01/2006
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 26 - n. 1
Voir la fiche