Approche thermique et exergétique du procédé d’un four rotatif par voie humide et évaluation du Cycle de Rankine Organique à récupération de chaleur perdue.
Thermal and exergetic approach to wet type rotary kiln process and evaluation of waste heat powered ORC (Organic Rankine Cycle).
Auteurs : USTAOGLU A., ALPTEKIN M., AKAY M. E.
Type d'article : Article, Étude de cas
Résumé
In this study, the energetic and exergetic performance analysis of a rotary kiln and cooling section in a cement factory using wet method was carried out based on the actual operational data. The energy and exergy efficiencies of the wet type rotary kiln are about 46% and 35%, respectively. The results showed that a great amount of heat energy of 30.5 MW is exhausted from the chimney of rotary kiln. In order to evaluate recovery capacity of exhausted gas, Organic Rankine Cycle (ORC) was considered and its energetic and exergetic performance were evaluated for isentropic and dry type fluids for different conditions. Isentropic fluid, R245fa shows the best performance while the dry fluid, R600a has the lowest performance. For condensation temperature of 303 K and evaporation pressure of 1500 kPa, the thermal and exergy efficiencies of R600a are 9.8% and 21.7% while the thermal and exergy efficiencies of R245fa are 13% and 29%, respectively. Isentropic fluids, R245fa, R142b can be used at high evaporator pressures and low condenser temperatures as R600 and R600a are not appropriate after a certain pressure since the efficiency remain stable. The exergy destruction rates in heat exchanger and evaporator are about 80% of the total exergy destruction.
Détails
- Titre original : Thermal and exergetic approach to wet type rotary kiln process and evaluation of waste heat powered ORC (Organic Rankine Cycle).
- Identifiant de la fiche : 30020775
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 112
- Date d'édition : 05/02/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.10.053
Liens
Voir d'autres articles du même numéro (39)
Voir la source
Indexation
-
Comparative Thermodynamic Analysis of the Perfo...
- Auteurs : MÉNDEZ-CRUZ L. E., GUTIÉRREZ-LIMON M. Á., LUGO-MÉNDEZ H., LUGO-LEYTE R., LOPEZ-ARENAS T., SALES-CRUZ M.
- Date : 04/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 7
- Formats : PDF
Voir la fiche
-
Low GWP alternatives to HFC-245fa in organic Ra...
- Auteurs : MOLÉS F., NAVARRO-ESBRÍ J., PERIS B., et al.
- Date : 10/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 71 - n. 1
Voir la fiche
-
CFD analysis of an ORC vane expander using Open...
- Auteurs : RANE S., BIANCHI G., KOVACEVIC A., CIPOLLONE R.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 25th International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental evaluation of HCFO-1233zd-E as HFC...
- Auteurs : MOLÉS F., NAVARRO-ESBRÍ J., PERIS B., et al.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche
-
Thermodynamic comparison of organic Rankine cyc...
- Auteurs : ZHAI X., HE D., YU Z., et al.
- Date : 20/07/2017
- Langues : Anglais
- Source : 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF