Alternatives à faible GWP pour le HFC-245fa dans des cycles organiques de Rankine pour la récupération de chaleur à basse température : HCFO-1233zd-E and HFO-1336mzz-Z.
Low GWP alternatives to HFC-245fa in organic Rankine cycles for low temperature heat recovery: HCFO-1233zd-E and HFO-1336mzz-Z .
Auteurs : MOLÉS F., NAVARRO-ESBRÍ J., PERIS B., et al.
Type d'article : Article
Résumé
HFC-245fa is a common working fluid used in Organic Rankine Cycles generating mechanical power from low temperature heat. This paper compares the predicted ORC performance of two novel low GWP working fluids, HCFO-1233zd-E and HFO-1336mzz-Z, to HFC-245fa over a wide range of evaporating temperatures, condensing temperatures and vapour superheat values. Expander power output, required pump power input, net cycle efficiencies, mass flow rates and turbine size parameters with HCFO-1233zd-E, HFO-1336mzz-Z and HFC-245fa were compared for a given thermal power input. HCFO-1233zd-E and HFO-1336mzz-Z are predicted to have attractive thermodynamic Rankine power cycle performance. HCFO-1233zd-E would require 10.3%e17.3% lower pump power and would enable up to 10.6% higher net cycle efficiencies than HFC-245fa over the range of cycle conditions examined in this paper. The turbine size required with HCFO-1233zd-E would be up to about 7.5%e10.2% larger than with HFC-245fa. HFO-1336mzz-Z would require 36.5%e41% lower pump power and would enable up to 17% higher net cycle efficiencies than HFC-245fa over the range of cycle conditions examined in this paper. The turbine size required with HFO-1336mzz-Z would be up to about 30.9%e41.5% larger than with HFC-245fa. HFO-1336mzz-Z cycle efficiency is benefitted substantially by a recuperator. The net cycle efficiency increases and the required turbine size decreases relative to HFC-245fa for HCFO-1233zd-E and for HFO-1336mzz-Z at higher evaporating and condensing temperatures.
Détails
- Titre original : Low GWP alternatives to HFC-245fa in organic Rankine cycles for low temperature heat recovery: HCFO-1233zd-E and HFO-1336mzz-Z .
- Identifiant de la fiche : 30013876
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 71 - n. 1
- Date d'édition : 10/2014
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2014.06.055
Liens
Voir d'autres articles du même numéro (9)
Voir la source
-
Experimental evaluation of HCFO-1233zd-E as HFC...
- Auteurs : MOLÉS F., NAVARRO-ESBRÍ J., PERIS B., et al.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche
-
Experimental investigation of low gwp alternati...
- Auteurs : JACOB T. A., FRONK B. M.
- Date : 31/07/2020
- Langues : Anglais
- Source : IIR Rankine Conference 2020.
- Formats : PDF
Voir la fiche
-
Thermal and exergetic approach to wet type rota...
- Auteurs : USTAOGLU A., ALPTEKIN M., AKAY M. E.
- Date : 05/02/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 112
Voir la fiche
-
GENSET waste heat recovery through an organic r...
- Auteurs : REN J., DAMLE N. G., CASKEY S., SHAFFER B. R., ZIVIANI D., GROLL E. A.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Design and analysis of the ORC system for the e...
- Auteurs : QI Z., CHANG Y., LI Y.
- Date : 20/07/2017
- Langues : Anglais
- Source : 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF
Voir la fiche