Document IIF
Bloc compresseur compact optimisé par éjecteur pour le dioxyde de carbone.
Compact ejector optimised compressor pack for carbon dioxide.
Numéro : 0800
Auteurs : HEERUP C., LARSEN L. F. S., MADSEN K. B.
Résumé
The present work investigates the impact of an ejector module on the performance of a CO2 compressor pack for supermarket applications. The European ecodesign criteria for condensing units were used as a framework to test and assess the performance of the system with and without active ejector, in terms of both capacity and energy efficiency. Seasonal energy performance ratio calculations were used to compare the test results. Results showed that at high ambient temperature the ejector increases the system capacity and efficiency by up to 34% and 24% respectively, thus enabling the downsizing of the compressor pack. However, the seasonal efficiency improvement was less than 5% at conditions corresponding to Northern Europe. Conditions corresponding to a high heat recovery demand in winter were also evaluated, which showed an increase in seasonal heating efficiency of up to 21%.
Documents disponibles
Format PDF
Pages : 11
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Compact ejector optimised compressor pack for carbon dioxide.
- Identifiant de la fiche : 30031840
- Langues : Anglais
- Sujet : Technologie
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0800
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Supermarchés, meubles de vente;
Systèmes à éjection, cycle à air, cycle Stirling, autres cycles;
Efficacité energétique, économie d'énergie;
Autres systèmes à économie / récupération d'énergie;
CO2 - Mots-clés : Supermarché; Système à éjecteur; Performance saisonniere; Efficacité énergétique; Récuperation de chaleur; Condition ambiante; Hiver; Essai; Calcul; COP; CO2; R744
-
Performance measurements of transcritical R744 ...
- Auteurs : BOTTICELLA F., LIU Z., ELBEL S.
- Date : 26/08/2020
- Langues : Anglais
- Source : 6th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Nantes, France, August 26-28 2020
- Formats : PDF
Voir la fiche
-
Comparative study of various supermarket refrig...
- Auteurs : GULLO P., PUROHIT N., SANKARDASGUPTA M., et al.
- Date : 06/04/2018
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Formats : PDF
Voir la fiche
-
Numerical analysis for performance comparison b...
- Auteurs : YOSHIDA T., ELBEL S.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Possible configurations of multiejector driven ...
- Auteurs : BLUST S., HAFNER A., BANASIAK K., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Development of commercial refrigeration systems...
- Auteurs : HAFNER A., POPPI S., NEKSÅ P., et al.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche