Document IIF
Caractéristiques de performance d'un [système de] conditionneur d'air combiné et interconnecté avec un réfrigérateur par un refroidisseur intermédiaire.
Performance characteristics of a combined air conditioner and refrigerator system interconnected via an intercooler.
Auteurs : HA D., JEONG J. H.
Type d'article : Article, Article de la RIF
Résumé
Convenience stores and supermarkets are equipped with air conditioner and refrigeration/freezer systems that are independently operated; these systems consume approximately 50%–60% of the total electric power used by the convenience store or supermarket. In this study, a combined system that can recover the condensation heat of the refrigeration system into the air conditioner using an intercooler is developed. Experimental investigations are conducted in order to investigate the performance characteristics of the combined system. Then, the proposed combined system is installed in a convenience store and operated for one year in order to measure the annual power consumption in a real environment. The proposed combined system exhibits an increase in the operation ratio, a reduction in defrosting operations, and a 32% reduction in the annual electric power consumption. The intercooler contributes to the reduction in power consumption, as does the use of a variable speed compressor. It is also found that the flow rate of the intercooler should be optimized when the air conditioning system is operated in the cooling mode.
Documents disponibles
Format PDF
Pages : 57-68
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance characteristics of a combined air conditioner and refrigerator system interconnected via an intercooler.
- Identifiant de la fiche : 30012898
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 49
- Date d'édition : 01/2015
Liens
Voir d'autres articles du même numéro (18)
Voir la source
-
Evaluation of Interaction Between Load of Refri...
- Auteurs : WEI C., FUJITA M., NARUMI D.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Promotion of energy efficient display cabinets.
- Auteurs : AXELL M., FAHLÉN P. O.
- Date : 1999
- Langues : Anglais
- Source : Refrigerated Transport, Storage and Retail Display.
- Formats : PDF
Voir la fiche
-
Energy Consumption Analysis for Coupling Air Co...
- Auteurs : KUSNANDAR, PERMANA I., CHIANG W., WANG F., LIOU C.
- Date : 07/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 13
- Formats : PDF
Voir la fiche
-
Energy savings in supermarket using control the...
- Auteurs : CHAI M.-L., SHIEN Y.-T., HSIEH W. D.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
FACTORS INFLUENCING OVERALL BUILDING EFFICIENCY.
- Auteurs : JONES J. R., BOONYATIKARN S.
- Date : 1990
- Langues : Anglais
Voir la fiche