Document IIF

Caractéristiques de transfert de chaleur lors de l'évaporation du dioxyde de carbone dans un tube lisse horizontal.

Evaporation heat transfer characteristics of carbon dioxide in a horizontal smooth tube.

Auteurs : YUN R., HWANG J. H., KIM Y. C., et al.

Résumé

The test tube had an inner diameter of 6.00 mm, a wall thickness of 1.00 mm, and a length of 1.6 m. A direct heating method was used to supply heat to the refrigerant. Experiments were conducted at saturation temperatures of 5 and 10 °C, mass fluxes from 170 to 320 kg/m2s and heat fluxes from 10 to 20 kW/m2. The heat transfer characteristics of carbon dioxide are explained by introducing the dryout phenomenon using a liquid entrainment model.

Documents disponibles

Format PDF

Pages : 2001-5

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Evaporation heat transfer characteristics of carbon dioxide in a horizontal smooth tube.
  • Identifiant de la fiche : 2003-0667
  • Langues : Anglais
  • Source : Thermophysical Properties and Transfer Processes of New Refrigerants.
  • Date d'édition : 03/10/2001

Liens


Voir d'autres communications du même compte rendu (60)
Voir le compte rendu de la conférence