Résumé
Heat pumps using CO2 (R744) are able to provide higher temperatures without significant losses in the COP. Furthermore, the transcritical refrigeration cycle has a gas cooler instead of a condenser which avoids high exergy losses due to large temperature differences during heat rejection. The necessity of simulations to speed up the development process brings focus on Modelica which gives an optimum to create models and cycles. Covering the control systems LabVIEW is used. Therefore the best simulation results can be achieved using a combination of both programs. The TISC-Server can be used for a co-simulation of LabVIEW and Modelica. The TISC-Server organizes the co-simulation setup by managing simulation programs, models, parameter and initialization settings, different simulation computers as well as the IP connections.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Co-simulation of a heat pump using R744 as the refrigerant.
- Identifiant de la fiche : 2011-0315
- Langues : Anglais
- Source : IIR/Eurotherm sustainable refrigeration and heat pump technology conference. Proceedings of the Eurotherm Seminar No. 88, Stockholm, Sweden, June 13-16, 2010.
- Date d'édition : 13/06/2010
Liens
Voir d'autres communications du même compte rendu (49)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
CO2 - Mots-clés : Simulation; Pompe à chaleur; Frigorigène; CO2
-
CO2 heat pump water heater: simulation and test...
- Auteurs : RIEBERER R., HALOZAN H.
- Date : 14/07/1998
- Langues : Anglais
- Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
Voir la fiche
-
The latest developments on the use of CO2 as re...
- Auteurs : SIENEL T.
- Date : 2006
- Langues : Anglais
- Source : IEA HPC Newsl. - vol. 24 - n. 3
Voir la fiche
-
Current status on heat pumps with carbon dioxid...
- Auteurs : NEKSÅ P., AARLIEN R.
- Date : 14/07/1998
- Langues : Anglais
- Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
Voir la fiche
-
Wybór czynnika ziebniczego dla pompy ciepla w d...
- Auteurs : FLAGA-MARYANCZYK A., SCHNOTALE J., NOVAK L., et al.
- Date : 06/2012
- Langues : Polonais
- Source : Chlodnictwo - vol. 47 - n. 6
Voir la fiche
-
Implementation of a CO2 ejector in a one MW hig...
- Auteurs : SCHROEDER A., KOEHLER J.
- Date : 16/04/2015
- Langues : Anglais
- Source : 6th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 16-18, 2015.
- Formats : PDF
Voir la fiche