Comment mesurer les fuites des conditionneurs d'air mobiles. Rapport final.
Establishing the leakage rates of mobile air conditioners. Final report.
Auteurs : Öko-Rech., Ecofys, SCHWARZ W., HARNISCH J.
Type de monographie : Rapport
Résumé
This report, prepared for the European Commission (DG Environment), determines the average annual leakage rate of HFC-134a from mobile air conditioning in the European Union of a "second generation" air conditioner. 300 measurements were carried out on air conditioners of cars up to seven years old. It focused entirely on "regular leakage" excluding "irregular emissions" attributable to system failures caused mostly by accidents, which takes place gradually from undamaged, functioning air conditioners. Extract from the table of contents: how to establish the leakage rate of mobile air conditioning systems?; measurement accuracy; composition and representativity of the sample; elimination of outliers from the sample; annual regular leakage rate of mobile air conditioners in EU-15. In the annexes: measurement protocol and participating garages. The report can be downloaded from the following Web site: http://europa.eu.int/comm/environment/climat/leakage_rates_final_report.pdf
Détails
- Titre original : Establishing the leakage rates of mobile air conditioners. Final report.
- Identifiant de la fiche : 2003-3075
- Langues : Anglais
- Sujet : Chiffres, économie
- Édition : European commission, dg environment - Allemagne/Allemagne
- Date d'édition : 17/04/2003
- Source : Source : 61 p. (21 x 29.7); fig.; tabl.; append.
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Indexation
-
Life cycle climate performance (LCCP) in mobile...
- Auteurs : VAINIO M.
- Date : 10/02/2003
- Langues : Anglais
- Source : MAC Summit 2003. Options to reduce greenhouse gas emissions due to mobile air conditioning [CD-ROM].
Voir la fiche
-
Study on the methodology to establish leakage r...
- Auteurs : Öko-Rech., SCHWARZ W.
- Date : 24/06/2005
- Langues : Anglais
Voir la fiche
-
Phase out of R-134a from vehicle air conditioni...
- Auteurs : HORROCKS P., VAINIO M.
- Date : 14/04/2004
- Langues : Anglais
- Source : MAC (mobile air conditioning) Summit 2004 [CD-ROM].
Voir la fiche
-
Establishment of leakage rates of mobile air co...
- Auteurs : Eur. Comm., Öko-Rech., SCHWARZ W.
- Date : 27/01/2007
- Langues : Anglais
Voir la fiche
-
Establishment of leakage rates of mobile air co...
- Auteurs : Eur. Comm., Öko-Rech., SCHWARZ W.
- Date : 31/01/2007
- Langues : Anglais
Voir la fiche