Comparaison de l'hydrocarbure R290 et de deux mélanges d'HFC, le R404A et le R410A, pour les applications frigorifiques à basse température.
Comparison of hydrocarbon R290 and two HFC blends R404A and R410A for low temperature refrigeration applications.
Auteurs : HWANG Y., JIN D. H., RADERMACHER R.
Résumé
To help provide a clearer understanding of the relative performance potential of R290 as compared with two HFCs (R404A and R410A) for commercial refrigeration, CEEE conducted an experimental evaluation program under ARI's GREEN Program. A 4 kW refrigeration system consisting of a unit cooler and a condensing unit, which was originally designed for R404A, served as the test unit. For safety reasons it was decided to minimize the charge of the R290 test unit by eliminating the refrigerant receiver. However, the impact of eliminating the receiver on system performance was evaluated. The condenser was also modified to contain a liquid subcooler circuit. Based on the optimization of the condenser, which is the most critical component of the low temperature commercial refrigeration system, a two circuit condenser was used for the testing of R410A while a three circuit condenser was used for the testing of R404A and R290. Under the same compressor efficiency assumption the COP improvement of R410A and R290 over R404A is 10% both for R410A and R290 under full load conditions and 4 and 5% for R410A and R290, respectively, under part load conditions. This result illustrates that the performance enhancement of R290 as compared to R404A is almost the same with R410A under both full load and part load conditions when the R410A compressor is optimized to the level of the R404A compressor.
Documents disponibles
Format PDF
Pages : 2005-3
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison of hydrocarbon R290 and two HFC blends R404A and R410A for low temperature refrigeration applications.
- Identifiant de la fiche : 2006-0552
- Langues : Anglais
- Source : Commercial Refrigeration. Thermophysical Properties and Transfer Processes of Refrigerants. Proceedings of the IIR International Conferences.
- Date d'édition : 30/08/2005
Liens
Voir d'autres communications du même compte rendu (140)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Hydrocarbures;
Mélanges - Mots-clés : R410A; Comparaison; R404A; Propane; Mélange binaire; Essai; COP; Frigorigène
-
Performance of CFC-502 alternative refrigerant ...
- Auteurs : JUNG D., HAM Y.
- Date : 30/08/2005
- Langues : Anglais
- Source : Commercial Refrigeration. Thermophysical Properties and Transfer Processes of Refrigerants. Proceedings of the IIR International Conferences.
- Formats : PDF
Voir la fiche
-
Comparison of R-290 and two HFC blends for walk...
- Auteurs : HWANG Y., JIN D. H., RADERMACHER R.
- Date : 06/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 4
- Formats : PDF
Voir la fiche
-
Experimental evaluation of five refrigerants as...
- Auteurs : MEYER J. P.
- Date : 24/06/2000
- Langues : Anglais
- Source : ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.
Voir la fiche
-
Evaluation of refrigerants.
- Auteurs : MEYER J. P.
- Date : 03/1999
- Langues : Anglais
- Source : S. A. Refrig. Aircond. - vol. 15 - n. 2
Voir la fiche
-
Le CO2 comme frigorigène : comparaisons avec d'...
- Auteurs : DOMBLIDES J. P., DUMINIL M., VRINAT G.
- Date : 05/2002
- Langues : Français
- Source : Rev. gén. Froid - vol. 91 - n. 1023
Voir la fiche