Document IIF
Comparaison des performances d’une pompe à chaleur en cascade fonctionnant au propane et au butane à l’échelle du laboratoire et à l’échelle industrielle.
Performance comparison of a lab and industrial scale propane-butane cascade heat pump.
Numéro : 1208
Auteurs : BLESS M., HOLMES T., MOEN O. M., NEKSÅ P., SCHLEMMINGER C.
Résumé
This paper presents a performance analysis of a lab-scale propane-butane cascade heat pump with a nominal heating capacity of 20 kWth at varying evaporation temperatures. Experimental data from the laboratory is compared with operational data from a scaled-up industrial pilot plant (300 kWth) using the same technical concept. The laboratory data successfully extends the operational range of the heat pump to an evaporation temperature of -15°C, achieving a maximum temperature lift of 124 K. The industrial plant shows higher combined COPs, reaching up to 3.7, and generally higher compressor efficiencies. This improved performance is likely due to multiple factors, although limited data from the industrial plant prevents a definitive conclusion. The study suggests that this heat pump technology is suitable for industrial applications requiring a wide range of temperature levels and lifts, particularly for simultaneous heating and cooling down to -15°C.
Documents disponibles
Format PDF
Pages : 12 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance comparison of a lab and industrial scale propane-butane cascade heat pump.
- Identifiant de la fiche : 30032722
- Langues : Anglais
- Source : 16th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2024). Proceedings. University of Maryland, College Park, Maryland, USA, August 11-14 2024
- Date d'édition : 08/2024
- DOI : http://dx.doi.org/10.18462/iir.gl2024.1208
Liens
Voir d'autres communications du même compte rendu (135)
Voir le compte rendu de la conférence
Indexation
-
Experimental investigation of a hydrocarbon pis...
- Auteurs : BAMIGBETAN O., EIKEVIK T. M., NEKSÅ P., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 24th International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Analysis of high temperature heat pumps applyin...
- Auteurs : STAVSET O., BANASIAK K., HAFNER A.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Performance characteristics of an air-cooled he...
- Auteurs : LEE H. S., YOON J. I., MOON C. G., et al.
- Date : 16/02/2006
- Langues : Anglais
- Source : Innovative Equipment and Systems for Comfort and Food Preservation.
- Formats : PDF
Voir la fiche
-
Experimental investigation of startup character...
- Auteurs : LIN J., WU J., ZHANG Z., et al.
- Date : 05/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 77
- Formats : PDF
Voir la fiche
-
Application d'une pompe à chaleur à haute tempé...
- Auteurs : HU B., WANG W., WANG K., et al.
- Date : 10/2011
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 32 - n. 141
- Formats : PDF
Voir la fiche