
Document IIF
Comparaison des performances de transfert de chaleur et de masse de différents absorbeurs/désorbeurs pour des pompes à chaleur à absorption compactes et efficaces.
Heat and mass transfer performance comparison of various absorbers/desorbers towards compact and efficient absorption heat pumps.
Résumé
Absorption heat pump (AHP) is significant for renewable/waste energy utilization to alleviate the energy crisis. Compact and energy-efficient AHP is essential for wider applications, and absorbers and desorbers play critical roles. To select the best-performing components for this purpose, heat and mass transfer characteristics are compared for different kinds of absorbers/desorbers, including microchannel membrane-based heat exchanger, plate heat exchanger, falling-film horizontal tube, and falling-film vertical tube. Heat and mass transfer models for each absorber/desorber have been established with validated accuracies. A wide range of geometrical parameters of absorbers/desorbers have been considered to obtain the variations of heat and mass transfer rates of each kind of absorber/desorber. Results indicate that the heat transfer coefficient and sorption rate (absorption/desorption) show a decreasing trend as the volume increases for all absorbers/desorbers. The microchannel membrane-based structure yields overwhelming heat and mass transfer performance in both absorbers and desorbers. The maximum heat transfer coefficient and sorption rate are up to 8.6 kW m−2 K−1 and 0.0150 kg m−2 s−1 for the microchannel membrane-based absorber and 4.2 kW m−2 K−1 and 0.0225 kg m−2 s−1 for the microchannel membrane-based desorber. This work provides a thorough comparison among various absorbers and desorbers and identifies their heat/mass transfer rate domains, facilitating structural design towards compact and efficient AHPs.
Documents disponibles
Format PDF
Pages : 19
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Heat and mass transfer performance comparison of various absorbers/desorbers towards compact and efficient absorption heat pumps.
- Identifiant de la fiche : 30028335
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 127
- Date d'édition : 07/2021
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2021.01.029
Liens
Voir d'autres articles du même numéro (25)
Voir la source
-
Unified thermodynamic model to calculate COP of...
- Auteurs : ZHU C., GLUESENKAMP K. R., YANG Z., et al.
- Date : 03/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 99
- Formats : PDF
Voir la fiche
-
Swirling flow for performance improvement of a ...
- Auteurs : SUI Z., ZHAI C., WU W.
- Date : 10/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 130
- Formats : PDF
Voir la fiche
-
Dynamic analysis of a single adsorbent particle...
- Auteurs : YILDIRIM Z. E., MOBEDI M., ULKU S.
- Date : 02/03/2014
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Formats : PDF
Voir la fiche
-
Study state simulation of absorption type heat ...
- Auteurs : WADA D., OHNO K., SAITO K.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Estudio simulación del estado de bomba de calor...
- Auteurs : WADA D., OHNO K., SAITO K.
- Date : 05/2012
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 40 - n. 447
- Formats : PDF
Voir la fiche