Comparaison des performances des dispositifs de récupération de chaleur sensible et totale avec un système à double tour à déshydratant liquide.
Comparison between the performance of sensible and total heat recovery devices and a liquid desiccant twin-tower system.
Numéro : pap. 3490
Auteurs : TAFELMEIER S., LONGO G. A., GASPARELLA A.
Résumé
A significant share of the energy demand in high performance buildings is related to mechanical ventilation. Aside traditional heat recovery devices, liquid desiccant systems can play an important role. The performance of liquid desiccant devices and consequently their potential in energy savings is complex to estimate due to the influence of operational conditions as well as of the physical properties of the fluids. A simple twin-tower configuration has been proposed as a reference system for assessing the control strategy and the potential of this technology to reduce the ventilation load. It consists of one absorption tower that treats the outside air and a second one that uses the exhaust air to restore the initial liquid desiccant conditions. This configuration operates as a total heat exchanger between the fresh and exhaust airstreams, with the liquid desiccant as heat and mass transfer medium. The heat and mass transfer between the fluid flows in the two towers has been modelled, and the energy saving potential in heating and cooling mode has been calculated based on annual hourly weather data. In order to assess the results, a comparison with the saving potential from conventional sensible and total heat recovery systems have been performed, considering 9 locations across Europe. Control strategies have been considered to limit total heat recovery in order to prevent excessive indoor humidity and/or to minimize dehumidification by cooling, comparing different room and ventilation conditions.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison between the performance of sensible and total heat recovery devices and a liquid desiccant twin-tower system.
- Identifiant de la fiche : 30024892
- Langues : Anglais
- Source : 2018 Purdue Conferences. 5th International High Performance Buildings Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (88)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Equipements d'humidification/déshumidification;
Transfert de chaleur;
Transfert de masse;
Autres systèmes à économie / récupération d'énergie - Mots-clés : Comparaison; Transfert de masse; Déshydratant liquide; Ventilation; Transfert de chaleur; Récuperation de chaleur; Modélisation; Économie d'energie; Conditionnement d'air; Chauffage
-
Effectiveness-NTU relation for packed bed liqui...
- Auteurs : REN C. Q.
- Date : 04/2008
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 51 - n. 7-8
Voir la fiche
-
Analytical solution of combined heat and mass t...
- Auteurs : LIU X. H., JIANG Y., QU K. Y.
- Date : 08/2008
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 51 - n. 17-18
Voir la fiche
-
Performance comparison of waste heat-driven des...
- Auteurs : COWIE M., LIAO X., RADERMACHER R.
- Date : 2003
- Langues : Anglais
- Source : ASHRAE Transactions. 2003 annual Meeting, Kansas City, Missouri, USA. Volume 109, part 2 + CD-ROM.
Voir la fiche
-
Investigation on solar desiccant dehumidificati...
- Auteurs : LI Y., YANG H.
- Date : 07/2008
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 28 - n. 10
Voir la fiche
-
Système de traitement d'air extérieur à déshydr...
- Auteurs : WANG J., LI Z., YUAN Y., et al.
- Date : 01/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 273
- Formats : PDF
Voir la fiche