Résumé
Describes the specific forms of the two systems, and analyses the difference of heat transfer area of evaporator when evaporation temperature of two systems is equal and the difference of evaporation temperature when heat transfer area of evaporator of two systems is equal. Compares their economic effects, operating energy consumption and reliability. The results show that for the equal evaporation temperature, the heat transfer area of the sewage heat exchanger in an indirect system is 3-5 times as large as that of evaporator, and the heat transfer area of evaporator in the direct system is 0.4-0.7 times larger than that of the indirect system; for the equal heat transfer area of evaporators, the evaporation temperature of direct system is 3-4°C lower than that of the indirect system; the investment of direct system is not really lower than that of indirect system, its energy consumption is lower at most 4% to 5%, and it is unreliable.
Documents disponibles
Format PDF
Pages : 111-114
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30003010
- Langues : Chinois
- Source : HV & AC - vol. 41 - n. 254
- Date d'édition : 09/2011
Liens
Voir d'autres articles du même numéro (15)
Voir la source
-
Comparison of energy supplies and consumptions ...
- Auteurs : XIONG T., YING Y., HAN B., YAN G., YU J.
- Date : 12/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 132
- Formats : PDF
Voir la fiche
-
Experimental study on fouling in the heat excha...
- Auteurs : BAI X., LUO T., CHENG K., et al.
- Date : 09/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 70 - n. 1
Voir la fiche
-
SEASONAL STORAGE OF SOLAR HEAT. UTILIZATION OF ...
- Auteurs : LEMMEKE L.
- Date : 1983
- Langues : Anglais
- Source : Swed. Counc. Build. Res. - D9:1983; 66 p.; fig.
Voir la fiche
-
ECHANGEUR DE CHALEUR POUR UNE INSTALLATION DE P...
- Auteurs : SCHOLT D.
- Date : 05/1981
- Langues : Allemand
- Source : Kälte + Klimatechnik (Die) - vol. 34 - n. 5
Voir la fiche
-
Experimental study on fault detection algorithm...
- Auteurs : KIM H. S., CHO M. K., KIM M. S.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche