Comparaison entre des conceptions de ventilation sous le plancher et au plafond pour des implantation de forte densité dans un centre de données.
Comparison between underfloor supply and overhead supply ventilation designs for data centre high-density clusters.
Auteurs : SCHMIDT R. R., IYENGAR M.
Résumé
Data centre facilities that house computer equipment represent a high capital investment and are typically designed to function for at least a few years, often without any down time. The computer equipment is usually designed with the assumption of rack air inlet temperatures in the 20-30°C range. Although there are many different perspectives for optimizing such a computing facility, ensuring device reliability by delivering uninterruptible power and cool air to the inlet of the electronics remains the most important goal. The objective of this paper is to compare two dominant airflow designs, namely, underfloor supply (raised floor) and overhead supply, with specific focus on the rack air inlet temperature. Numerical models of two data centre sections, representing underfloor air supply and overhead air supply designs, were constructed utilizing commercial software, and the data generated from a parametric study were analyzed. The model constitutes a half symmetry section of a 40-rack data centre that is arranged in a cold aisle/hot aisle fashion. Temperature data were collected at several locations at the inlet to the racks. The effects of two different airflow designs (raised floor versus non-raised floor), supply airflow fraction, location of rack, and height of measurement were studied.
Détails
- Titre original : Comparison between underfloor supply and overhead supply ventilation designs for data centre high-density clusters.
- Identifiant de la fiche : 2009-0790
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
- Date d'édition : 27/01/2007
Liens
Voir d'autres communications du même compte rendu (17)
Voir le compte rendu de la conférence
Indexation
-
Comparison of overhead and underfloor air deliv...
- Auteurs : SORELL V., ESCALANTE S., YANG J.
- Date : 2005
- Langues : Anglais
- Source : ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
Voir la fiche
-
Le conditionnement d'air de pièce et les soluti...
- Auteurs : RAKOCZY T.
- Date : 04/1993
- Langues : Allemand
- Source : Klima Kälte Heiz. - vol. 21 - n. 4
Voir la fiche
-
Climatiser par le faux plancher.
- Auteurs : TRANCART M.
- Date : 11/1993
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 784
Voir la fiche
-
Airflow distribution through perforated tiles i...
- Auteurs : RAMBO J., NELSON G., JOSHI Y.
- Date : 23/06/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
Voir la fiche
-
FLOOR DISTRIBUTION METHOD FOR SUPPLY AIR.
- Auteurs : BALANDINA L. I.
- Date : 07/08/1983
- Langues : Anglais
- Source : [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
- Formats : PDF
Voir la fiche