Conception et évaluation d’un appareil à circuit fermé pour les tests de charge.

Closed-loop apparatus (CLA) design and assessment for load-based testing.

Numéro : 2597

Auteurs : KIM D., DHILLON P., KIDAMBI A., HORTON W. T., BRAUN J. E.

Résumé

The existing testing and rating procedure for split-type residential heat pumps in the United States is based on AHRI 210/240, which provides a standardized metric for assessing equipment performance that is based on steady-state tests where the equipment native controls are overridden. In an effort to improve testing and rating of heat pumps, a load-based testing methodology has recently been developed that accounts for the effect of the integrated controls and thermostat. In this approach, a test unit with its thermostat dynamically responds to emulated building loads in real-time, continuously adjusting indoor test room conditions based on a virtual building model, while the outdoor test conditions are maintained at a steady state. For typical load-based testing, two psychrometric chambers are used and only one unit can be tested at a time. Load-based testing can be time-consuming and expensive, particularly for residential split systems when different combinations of indoor and outdoor units need to be tested. Additionally, implementing load-based testing in psychrometric chambers necessitates controller and software upgrades for the rooms to enable virtual building emulation. To address these issues, this paper proposes a closed-loop apparatus (CLA) featuring integrated controls and automated software for load-based testing. In this setup, the indoor unit is installed in the CLA, while the outdoor unit is installed in a single psychrometric chamber. The CLA maintains indoor test unit return air (RA) conditions in real-time based on the virtual building temperature and humidity set points during load-based tests. Test unit performance is measured in real-time, and the indoor unit supply air is reconditioned with an electrical heater, cooling coil, and humidifier in the air loop. In this setup, multiple outdoor units could be positioned within a single psychrometric chamber, and multiple CLAs could be coupled with various indoor units. This configuration would allow for the simultaneous testing of multiple units, streamlining the testing process.

Documents disponibles

Format PDF

Pages : 10 p.

Disponible

Gratuit

Détails

  • Titre original : Closed-loop apparatus (CLA) design and assessment for load-based testing.
  • Identifiant de la fiche : 30033014
  • Langues : Anglais
  • Sujet : Réglementation
  • Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 17/07/2024

Liens


Voir d'autres communications du même compte rendu (187)
Voir le compte rendu de la conférence