Document IIF
Configuration de l'écoulement, débit massique, distribution de la pression et de la température et écoulement diphasique du HFC-134a à l'intérieur d'orifices de tubes courts.
Flow pattern, mass flow rate, pressure distribution, and temperature distribution of two-phase flow of HFC-134a inside short-tube orifices.
Auteurs : NILPUENG K., SUPAVARASUWAT C., WONGWISES S.
Type d'article : Article, Article de la RIF
Résumé
New experimental data on the influence of short-tube orifice configuration, including diameter, length, length-to-diameter ratio (L/D), and orientation on the flow pattern, mass flow rate, and pressure distribution of HFC-134a inside the short-tube orifice are presented. Short-tube orifice diameters ranging between 0.605 and 1.2 mm with L/D ranging between 1.87 and 33 are used in the experiments. Three different forms of the metastable liquid flow, which are metastable liquid core flow, conical metastable liquid core flow, and full metastable liquid flow are visually observed. The short-tube orifice diameter has a significant effect on the increase in the flow rate. Conversely, the change in the orientation of the test section has no significant effect on the flow rate. The choke flow phenomenon disappears inside the short-tube orifice when L/D is less than 2.91. Based on the present data, a correlation for predicting the mass flow rate through short-tube orifices is proposed.
Documents disponibles
Format PDF
Pages : pp. 1864-1875
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Flow pattern, mass flow rate, pressure distribution, and temperature distribution of two-phase flow of HFC-134a inside short-tube orifices.
- Identifiant de la fiche : 2009-2259
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 8
- Date d'édition : 12/2009
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
-
Thèmes :
HFC;
Transfert de chaleur;
Ecoulement diphasique - Mots-clés : Écoulement diphasique; R134a; Géometrie; Tube; Température; Orifice; Experimentation; Frigorigène; Chute de pression
-
Experimental investigation of two-phase flow ch...
- Auteurs : NILPUENG K., WONGWISES S.
- Date : 08/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 5
- Formats : PDF
Voir la fiche
-
Experimental study of evaporation pressure drop...
- Auteurs : LIE Y. M., SU F. Q., LAI R. L., et al.
- Date : 01/2008
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 51 - n. 1-2
Voir la fiche
-
Two-phase frictional pressure drop in U-type wa...
- Auteurs : CHEN I. Y., WU Y. S., HU R., et al.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Pressure drop correlation for oil-refrigerant R...
- Auteurs : CASTRO H. O. S., GASCHE J. L., PRATA A. T.
- Date : 05/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 3
- Formats : PDF
Voir la fiche
-
Two-phase frictional pressure drop and flow beh...
- Auteurs : DE KERPEL K., DE SCHAMPHELEIRE S., DE KEULENAER T., et al.
- Date : 25/01/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 93
Voir la fiche