CONVECTION FORCEE PAR DES LIQUIDES POUR DES THERMOMETRES INDUSTRIELS DANS DES ECOULEMENTS CROISES.

FORCED CONVECTION FROM LIQUIDS TO INDUSTRIAL THERMOMETERS IN CROSSFLOW.

Auteurs : CHOHAN R. K.

Type d'article : Article

Résumé

UNE CORRELATION DU TEMPS DE REPONSE FOURNIT LE TEMPS DE REPONSE THERMIQUE T ET LE COEFFICIENT DE TRANSFERT DE CHALEUR H. EN UTILISANT CETTE CORRELATION ET DES TEMPERATURES DE REPONSE OBTENUES PAR DES EXPERIENCES, ON A ANALYSE DES CORRELATIONS DE TRANSFERT DE CHALEUR. CES CORRELATIONS N'ETANT PAS VALABLES POUR LES NOMBRES DE REYNOLDS FAIBLES, UNE RELATION SATISFAISANTE ENTRE T ET L/H POUR CES NOMBRES DE REYNOLDS NE PEUT ETRE OBTENUE. LA CORRELATION CHURCHILL-BERNSTEIN COUVRE UNE LARGE GAMME DE NOMBRES DE REYNOLDS FAIBLE ET MOYENS. AFIN D'OBTENIR DES PARAMETRES POUR LA CORRELATION DU TEMPS DE REPONSE, ON SUGGERE QU'UNE BANDE DE LIGNES DROITES PARALLELES SOIT ELABOREE POUR CONTENIR LA PLUPART DES RESULTATS T 1/H POUR UN THERMOMETRE.

Détails

  • Titre original : FORCED CONVECTION FROM LIQUIDS TO INDUSTRIAL THERMOMETERS IN CROSSFLOW.
  • Identifiant de la fiche : 1989-1743
  • Langues : Anglais
  • Source : Heat Recov. Syst. CHP - vol. 8 - n. 4
  • Date d'édition : 1988

Liens


Voir d'autres articles du même numéro (4)