FORCED CONVECTION FROM LIQUIDS TO INDUSTRIAL THERMOMETERS IN CROSSFLOW.

Author(s) : CHOHAN R. K.

Type of article: Article

Summary

A RESPONSE TIME CORRELATION RELATES THERMAL RESPONSE TIME, T, AND THE HEAT TRANSFER COEFFICIENT (H). USING THIS CORRELATION AND EXPERIMENTALLY OBTAINED RESPONSE TIMES, A NUMBER OF HEAT TRANSFER CORRELATIONS HAVE BEEN ANALYSED. THOSE CORRELATIONS NOT PROVEN VALID FOR LOW REYNOLDS NUMBERS MAY NOT GIVE SATISFACTORY AGREEMENT BETWEEN T AND L/H FOR THESE REYNOLDS NUMBERS. THE CHURCHILL-BERNSTEIN CORRELATION COVERS A WIDE RANGE OF LOW AND MODERATE REYNOLDS NUMBERS. IT IS SUGGESTED THAT TO OBTAIN PARAMETERS FOR THE RESPONSE TIME CORRELATION, A BAND OF STRI E T L/H DATA FOR A THERMOMETER.

Details

  • Original title: FORCED CONVECTION FROM LIQUIDS TO INDUSTRIAL THERMOMETERS IN CROSSFLOW.
  • Record ID : 1989-1743
  • Languages: English
  • Source: Heat Recov. Syst. CHP - vol. 8 - n. 4
  • Publication date: 1988